[Assessment of left ventricular twist in type 2 diabetes mellitus by using two-dimensional ultrasound speckle tracking imaging].

Zhejiang Da Xue Xue Bao Yi Xue Ban

Department of Ultrasonography, First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China.

Published: September 2014

Objective: To evaluate the left ventricular twist characteristics in patients with type 2 diabetes by using two-dimensional speckle tracking imaging (STI).

Methods: Ninety-three patients with type 2 diabetes admitted in Zhejiang Hospital from May 2012 to September 2013 were enrolled. According to left ventricular ejection fraction (LVEF), patients were divided into two groups: normal left ventricular systolic function group (group A, LVEF≥0.50, n=46) and abnormal left ventricular systolic function group (group B, LVEF <0.50, n=47). Forty-six healthy subjects were selected as normal controls. STI was applied to quantitatively analyze the left ventricular twist. Correlation of the peak of left ventricular twist angle (Peaktw), aortic valve closure time twist angle (AVCtw), and mitral valve opening time twist angle (MVOtw) with LVEF, Tei index, E/A, and E/e was evaluated. Consistency check for STI was conducted to assess its stability and reliability.

Results: The Peaktw, AVCtw, and MVOtw in group A were significantly elevated than those in normal controls (P<0.05). The Peaktw, AVCtw, and MVOtw in group B was lower than those in normal controls and group A (P<0.05). In diabetic patients, the Peaktw, AVCtw, MVOtw were positively correlated with LVEF (r=0.968, 0.966, 0.938;P<0.05) and E/A (r=0.798, 0.790, 0.788; P<0.05), and were negatively correlated with Tei index (r=-0.834, -0.811, -0.797; P<0.05) and E/e (r=-0.823, -0.805, -0.771; P<0.05). The agreement between measurers and within measurers of Peaktw was satisfactory (between measurers: R=0.957, bias=-0.1, 95% consistency limit=-2.8-2.7; within measurer: R=0.964, bias=-0.2, 95% consistency limits=-2.7-2.2).

Conclusion: STI can be used for early recognition of abnormal changes of cardiac function in type 2 diabetic mellitus patients, with high stability and reliability.

Download full-text PDF

Source
http://dx.doi.org/10.3785/j.issn.1008-9292.2014.09.003DOI Listing

Publication Analysis

Top Keywords

left ventricular
20
type diabetes
12
ventricular twist
8
speckle tracking
8
patients type
8
ventricular systolic
8
systolic function
8
function group
8
group group
8
ventricular
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!