A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the internal construct validity of the Personal Care Participation Assessment and Resource Tool (PC-PART) using Rasch analysis. | LitMetric

Background: The Personal Care Participation Assessment and Resource Tool (PC-PART) is a 43-item, clinician-administered assessment, designed to identify patients' unmet needs (participation restrictions) in activities of daily living (ADL) required for community life. This information is important for identifying problems that need addressing to enable, for example, discharge from inpatient settings to community living. The objective of this study was to evaluate internal construct validity of the PC-PART using Rasch methods.

Methods: Fit to the Rasch model was evaluated for 41 PC-PART items, assessing threshold ordering, overall model fit, individual item fit, person fit, internal consistency, Differential Item Functioning (DIF), targeting of items and dimensionality. Data used in this research were taken from admission data from a randomised controlled trial conducted at two publically funded inpatient rehabilitation units in Melbourne, Australia, with 996 participants (63% women; mean age 74 years) and with various impairment types.

Results: PC-PART items assessed as one scale, and original PC-PART domains evaluated as separate scales, demonstrated poor fit to the Rasch model. Adequate fit to the Rasch model was achieved in two newly formed PC-PART scales: Self-Care (16 items) and Domestic Life (14 items). Both scales were unidimensional, had acceptable internal consistency (PSI =0.85, 0.76, respectively) and well-targeted items.

Conclusions: Rasch analysis did not support conventional summation of all PC-PART item scores to create a total score. However, internal construct validity of the newly formed PC-PART scales, Self-Care and Domestic Life, was supported. Their Rasch-derived scores provided interval-level measurement enabling summation of scores to form a total score on each scale. These scales may assist clinicians, managers and researchers in rehabilitation settings to assess and measure changes in ADL participation restrictions relevant to community living.

Trial Registration: Data used in this research were gathered during a registered randomised controlled trial: Australian and New Zealand Clinical Trials Registry ACTRN12609000973213. Ethics committee approval was gained for secondary analysis of data for this study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4226893PMC
http://dx.doi.org/10.1186/s12913-014-0543-zDOI Listing

Publication Analysis

Top Keywords

internal construct
12
construct validity
12
fit rasch
12
rasch model
12
pc-part
9
personal care
8
care participation
8
participation assessment
8
assessment resource
8
resource tool
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!