Purpose: The purpose of this study was to obtain a set of correction factors of the radiophotoluminescent glass dosimeter (RGD) output for field size changes and wedge insertions.
Methods: Several linear accelerators were used for irradiation of the RGDs. The field sizes were changed from 5 × 5 cm to 25 × 25 cm for 4, 6, 10, and 15 MV x-ray beams. The wedge angles were 15°, 30°, 45°, and 60°. In addition to physical wedge irradiation, nonphysical (dynamic/virtual) wedge irradiations were performed.
Results: The obtained data were fitted with a single line for each energy, and correction factors were determined. Compared with ionization chamber outputs, the RGD outputs gradually increased with increasing field size, because of the higher RGD response to scattered low-energy photons. The output increase was about 1% per 10 cm increase in field size, with a slight difference dependent on the beam energy. For both physical and nonphysical wedged beam irradiation, there were no systematic trends in the RGD outputs, such as monotonic increase or decrease depending on the wedge angle change if the authors consider the uncertainty, which is approximately 0.6% for each set of measured points. Therefore, no correction factor was needed for all inserted wedges. Based on this work, postal dose audits using RGDs for the nonreference condition were initiated in 2010. The postal dose audit results between 2010 and 2012 were analyzed. The mean difference between the measured and stated doses was within 0.5% for all fields with field sizes between 5 × 5 cm and 25 × 25 cm and with wedge angles from 15° to 60°. The standard deviations (SDs) of the difference distribution were within the estimated uncertainty (1SD) except for the 25 × 25 cm field size data, which were not reliable because of poor statistics (n = 16).
Conclusions: A set of RGD output correction factors was determined for field size changes and wedge insertions. The results obtained from recent postal dose audits were analyzed, and the mean differences between the measured and stated doses were within 0.5% for every field size and wedge angle. The SDs of the distribution were within the estimated uncertainty, except for one condition that was not reliable because of poor statistics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.4898596 | DOI Listing |
Imaging Sci Dent
December 2024
Department of Oral and Maxillofacial Radiology, The Institute for Postgraduate Dental Education, Jönköping, Sweden.
Purpose: This study investigated the impact of the field of view (FOV), voxel size, and exposure parameters on the contrast-to-noise ratio (CNR) in cone-beam computed tomography (CBCT).
Materials And Methods: A SedentexCT phantom was scanned using 3D Accuitomo 170 across 3 FOVs (40×40 mm, 60×60 mm, 80×80 mm). Each FOV had 4 settings for kVp and 3 for mA.
Physiol Mol Biol Plants
December 2024
Department of Bioengineering and Biotechnology, Birla Institute of Technology, Mesra, Ranchi, Jharkhand 835215 India.
Unlabelled: DNA methylation is a paramount epigenetic mark that helps balance gene expression post-transcriptionally. Its effect on specific genes determines the plant's holistic development and acclimatization during adversities. L.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Department of Physics, University of Washington, Seattle, WA, USA.
Wide field of view and light weight optics are critical for advanced eyewear, with applications in augmented/virtual reality and night vision. Conventional refractive lenses are often stacked to correct aberrations at a wide field of view, leading to limited performance and increased size and weight. In particular, simultaneously achieving a wide field of view and large aperture for light collection is desirable but challenging to realize in a compact form-factor.
View Article and Find Full Text PDFJ Korean Assoc Oral Maxillofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang, Korea.
The submandibular displacement of a mandibular third molar residual root presents major challenges to oral and maxillofacial surgeons due to the proximity to critical anatomical structures such as the lingual nerve and sublingual artery. Preoperative imaging can approximate the location of the residual tooth root; however, accurately determining its exact position is difficult because of the dynamic nature of the mandible and the difficulty of real-time synchronization of imaging. This study presents the successful extraction of a residual mandibular third molar root in a 67-year-old female patient achieved using a magnetic field-based navigation system.
View Article and Find Full Text PDFTicks Tick Borne Dis
December 2024
Quantitative Veterinary Epidemiology, Wageningen University & Research, Wageningen, the Netherlands.
Biological control of ticks using entomopathogenic fungi (EPF) is a highly desired alternative to chemical acaricides for the control of tick-borne pathogens. For Metarhizium anisopliae isolate ICIPE 7, one of these EPFs, efficacy against multiple tick species has been demonstrated in laboratory and field settings. However, we currently have little quantitative understanding of how EPFs can impact transmission.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!