Comparison of ⁶⁸Ga-DOTATATE PET-CT, ¹⁸F-FDG PET-CT and 99mTc-(V)DMSA scintigraphy in the detection of recurrent or metastatic medullary thyroid carcinoma.

Nucl Med Commun

Departments of aNuclear Medicine bInternal Medicine, Endocrinology and Metabolism Division cDepartment of Biostatistics and Medical Informatics, Istanbul Medical Faculty, Istanbul University, Istanbul, Turkey.

Published: March 2015

Purpose: We aimed to compare the efficacies of gallium-68 (68Ga) DOTATATE PET-computed tomography (CT), fluorine-18 fluorodeoxyglucose (18F-FDG) PET-CT and technetium-99m (99mTc)-(V)DMSA scintigraphy in the detection of residual/metastatic medullary thyroid carcinoma (MTC).

Materials And Method: We retrospectively evaluated DOTATATE PET-CT, 18F-FDG PET-CT and (V)DMSA scintigraphy of 22 MTC patients, all taken within a 6-month period in each patient, because of high levels of calcitonin (Ct) and carcinoembryonic antigen (CEA). We investigated the relationships between the results of the imaging modalities and tumour marker levels and the sporadic versus hereditary nature of the disease, as well as the effect of imaging results on patient management.

Results: The ages of the patients at diagnosis were between 20 and 69 years. The median levels of Ct and CEA were 871.5 pg/ml and 11.2 ng/ml, respectively. In the patient-based analysis, we observed at least one focus of abnormal uptake in 15 of 22 DOTATATE PET-CT (68.2% sensitivity), eight of 18 18F-FDG PET-CT (44.4% sensitivity) and five of 15 (V)DMSA scans (33.3% sensitivity). These data showed a significant difference between DOTATATE PET-CT and (V)DMSA scintigraphy (P=0.016), whereas the relationships between DOTATATE PET-CT and 18F-FDG PET-CT and between 18F-FDG PET-CT and (V)DMSA scintigraphy showed no significant differences (P>0.05). In the lesion-based analysis, 134 lesions were detected with DOTATATE PET-CT, 76 lesions with 18F-FDG PET-CT and nine lesions with (V)DMSA scintigraphy.

Conclusion: DOTATATE PET-CT is an efficient imaging modality in MTC patients with increased Ct and CEA (especially >1000 pg/ml and 50 ng/ml, respectively) for localizing recurrent or metastatic disease. 18F-FDG PET-CT can be performed if DOTATATE PET-CT is not available, but (V)DMSA scintigraphy is not recommended.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MNM.0000000000000240DOI Listing

Publication Analysis

Top Keywords

18f-fdg pet-ct
28
dotatate pet-ct
28
pet-ct
16
pet-ct vdmsa
16
vdmsa scintigraphy
16
pet-ct 18f-fdg
12
99mtc-vdmsa scintigraphy
8
scintigraphy detection
8
recurrent metastatic
8
medullary thyroid
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!