A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimation of cardiac output and pulmonary vascular resistance by contrast echocardiography transit time measurement: a prospective pilot study. | LitMetric

Background: Studies with other imaging modalities have demonstrated a relationship between contrast transit and cardiac output (CO) and pulmonary vascular resistance (PVR). We tested the hypothesis that the transit time during contrast echocardiography could accurately estimate both CO and PVR compared to right heart catheterization (RHC).

Methods: 27 patients scheduled for RHC had 2D-echocardiogram immediately prior to RHC. 3 ml of DEFINITY contrast followed by a 10 ml saline flush was injected, and a multi-cycle echo clip was acquired from the beginning of injection to opacification of the left ventricle. 2D-echo based calculations of CO and PVR along with the DEFINITY-based transit time calculations were subsequently correlated with the RHC-determined CO and PVR.

Results: The transit time from full opacification of the right ventricle to full opacification of the left ventricle inversely correlated with CO (r=-0.61, p<0.001). The transit time from peak opacification of the right ventricle to first appearance in the left ventricle moderately correlated with PVR (r=0.46, p<0.01). Previously described echocardiographic methods for the determination of CO (Huntsman method) and PVR (Abbas and Haddad methods) did not correlate with RHC-determined values (p = 0.20 for CO, p = 0.18 and p = 0.22 for PVR, respectively). The contrast transit time method demonstrated reliable intra- (p<0.0001) and inter-observer correlation (p<0.001).

Conclusions: We describe a novel method for the quantification of CO and estimation of PVR using contrast echocardiography transit time. This technique adds to the methodologies used for noninvasive hemodynamic assessment, but requires further validation to determine overall applicability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4223835PMC
http://dx.doi.org/10.1186/1476-7120-12-44DOI Listing

Publication Analysis

Top Keywords

transit time
16
cardiac output
8
output pulmonary
8
pulmonary vascular
8
vascular resistance
8
contrast echocardiography
8
opacification left
8
left ventricle
8
full opacification
8
transit
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!