We present a reduced-phase dual-illumination interferometer (RPDII) that measures the topography of a sample with large step height variation. We experimentally demonstrate the basic principle and the feasibility of this novel single-shot quantitative phase imaging. Two beams of this interferometer illuminate a sample at different incident angles, and two phases of the different incident angles and their phase difference are simultaneously recorded using three spatial frequencies. The relative phase difference between two beams of an RPDII can be controlled by adjusting the angle such that the maximum phase difference is smaller than 2π, and thus there is no phase wrapping ambiguity in the reconstructed phase. One 4f optical system with a transmission grating is used to illuminate the sample with two collimated beams incident at different angles. The feasibility of this technique is demonstrated by measuring the thicknesses of two stepped metal layers with heights of 150 and 660 μm. Although the change in stepped height is more than 1000 times the wavelength of the laser used in our interferometer, the thicknesses of these two metal layers are successfully obtained without the use of an unwrapping algorithm.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.39.005740DOI Listing

Publication Analysis

Top Keywords

incident angles
12
phase difference
12
reduced-phase dual-illumination
8
dual-illumination interferometer
8
illuminate sample
8
metal layers
8
phase
6
interferometer
4
interferometer measuring
4
measuring large
4

Similar Publications

Objective: The goal of this study was to compare the impact of using a lower thoracic (LT) versus upper lumbar (UL) level as the upper instrumented vertebra (UIV) on clinical and radiographic outcomes following minimally invasive surgery for adult spinal deformity.

Methods: A multicenter retrospective study design was used. Inclusion criteria were age ≥ 18 years, and one of the following: coronal Cobb angle > 20°, sagittal vertical axis > 50 mm, pelvic tilt > 20°, pelvic incidence-lumbar lordosis mismatch > 10°.

View Article and Find Full Text PDF

There are limited studies on the phase angle (PhA) and sarcopenic obesity (SO) in the Chinese population. This study aimed to establish 50 kHz-PhA reference data for SO population, and to evaluate the correlation between 50 kHz-PhA and SO. A total of 10,312 participants including 5415 men and 4897 women were enrolled in this study, and their resistance and reactance at 50 kHz, and body composition parameters were measured a segmental multifrequency bioelectrical impedance analysis device (InBody 720).

View Article and Find Full Text PDF

Ankle fractures are among the most common bone injuries, which are often accompanied by soft tissue injuries. Proper management of these fractures is crucial to promote healing and minimize complications. This study explores the effects of 2 treatment methods for ankle fractures: open reduction and internal fixation and manual reduction followed by plaster external fixation.

View Article and Find Full Text PDF

Objectives: To compare lag-screw slide and revision surgery rate between two generations of the Stryker Gamma cephalomedullary nail (Stryker, Kalamazoo, MI).

Methods: Design: Retrospective chart review.

Setting: Single academic, Level-1 Trauma Center.

View Article and Find Full Text PDF

BACKGROUND Vestibular schwannoma is a slow-growing benign tumor arising from the 8th cranial nerve. It can originate in the cerebellopontine angle (CPA). This retrospective study aimed to investigate the factors associated with outcomes following surgical resection of vestibular schwannoma in the CPA in 30 patients at a single center in Turkey, focusing on postoperative intratumoral hemorrhage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!