A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The influence of hemostatic agents on dentin and enamel surfaces and dental bonding: a systematic review. | LitMetric

The influence of hemostatic agents on dentin and enamel surfaces and dental bonding: a systematic review.

J Am Dent Assoc

Dr. Pereira is a professor, Department of Dentistry, School of Health Sciences, University of Brasília, Campus Darcy Ribeiro, CEP: 70910-900, Brazil, e-mail Address correspondence to Dr. Pereira.

Published: November 2014

AI Article Synopsis

  • The review focused on the impact of hemostatic agents used in dentistry on the surfaces of dentin and enamel, specifically how they affect the bonding of adhesive systems and resin cements.
  • Out of the studies analyzed, a majority showed that applying hemostatic agents led to a significant reduction in bond strength, especially with self-etching adhesives, and increased microleakage in contaminated dentin.
  • Practical findings suggest that hemostatic agents can negatively alter dentin surface characteristics, but a 60-second application of ethylenediaminetetraacetic acid followed by water can help restore bond strength in self-etching systems.

Article Abstract

Background: Hemostatic agents have been used clinically in dentistry for many years to control bleeding. The authors reviewed scientific publications in which researchers investigated the effects of hemostatic agents on dentin and enamel surfaces and on bonding of adhesive systems and resin cements.

Types Of Studies Reviewed: The authors screened PubMed and Scopus databases for studies in English published from 1980 to 2013. They read the titles and abstracts to identify literature that fulfilled the inclusion criteria. The authors included studies in which researchers evaluated the hemostatic action on the dentin and enamel surfaces or its influence on the bond strength of adhesive systems or resin cements. They used cross-referencing to identify more articles.

Results: Twenty in vitro studies met the inclusion criteria. Investigators in 12 of these studies evaluated the bond strength to contaminated dentin. Investigators in 10 of these studies reported a significant decrease in bond strength. Those in two studies evaluated the influence of a hemostatic agent on the dental enamel and reported decreases in bond strength. Researchers also reported significant increases in microleakage of self-etching adhesives on contaminated dentin. Scanning electron microscopy revealed partial removal of the smear layer or an etching effect of dentin as a result of the application of hemostatic agents on dentin.

Practical Implications: Adhesive procedures may be affected adversely when performed on dentin and enamel contaminated by hemostatic agents. Hemostatic agents may induce changes in the dentin surface morphology. The results of this review indicate that the bond strength of self-etching adhesive systems is affected more negatively than is that of etch-and-rinse systems. The authors found that a 60-second application of ethylenediaminetetraacetic acid followed by a water spray restored the bond strength of a self-etching adhesive to dentin; use of phosphoric acid for 15 seconds followed by a water spray also was an effective cleaning method. Direct comparison of selected studies was not possible, however, mainly because of methodological differences hampering definitive conclusions.

Download full-text PDF

Source
http://dx.doi.org/10.14219/jada.2014.84DOI Listing

Publication Analysis

Top Keywords

hemostatic agents
24
bond strength
24
dentin enamel
16
enamel surfaces
12
adhesive systems
12
dentin
9
influence hemostatic
8
agents dentin
8
systems resin
8
studies
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!