Objective: The objective was to evaluate percutaneous computed tomography (CT) and fluoroscopy-guided injection of bone cement for consolidation of loosened posterior arthrodesis performed by radiologists.

Methods: A single-centre prospective study involving four consecutive patients (three women, one man) suffering from screw loosening (three at the vertebral level, one at the iliac wing level) after Posterior Lumbar Interbody Fusion (PLIF) treatment was done. The average age was 80 years. Surgical treatment was not indicated or not wished for by the patients. Institutional review board approval and informed consent were obtained. Percutaneous consolidation was performed by an interventional radiologist under CT and fluoroscopy guidance. The path of the trocars was made outside loosened screws bilaterally. Follow-up was assessed using the Visual Analog Scale (VAS).

Results: In all cases, bone cement was successfully placed around the loosened screw. The mean volume of cement that was injected was 3 ml. No cement leakage was observed. No neurological complication occurred. Using VAS, pain decreased from more than 9/10 preoperatively to less than 2/10 the day after the procedure for all patients (p < 0.05).

Conclusion: This study suggests that loosening of spine arthrodesis could be successfully treated by percutaneous injection of bone cement under CT and fluoroscopy guidance.

Key Points: • PLIF is one of the surgical techniques for spinal arthrodesis. • Treatment indications are degenerative disease or instability following trauma, tumour, or infection. • Screw loosening is a frequent complication that can occur after surgery. • Percutaneous facet consolidation under dual guidance seems to be a feasible technique. • The procedure is performed under local anaesthesia using a minimally invasive approach.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-014-3475-4DOI Listing

Publication Analysis

Top Keywords

percutaneous consolidation
8
consolidation loosened
8
fluoroscopy guidance
8
bone cement
8
loosened
4
loosened spine
4
spine arthrodesis
4
arthrodesis fluoroscopy
4
guidance radiologists
4
radiologists technique
4

Similar Publications

In vivo Safety and Feasibility of a Computed Tomography-Guided Robotic Device for Percutaneous Needle Placement in Bone.

J Vasc Interv Radiol

January 2025

Gustave Roussy (GR), Département d'Anesthésie Chirurgie et Interventionnelle (DACI), Service d'Imagerie Thérapeutique, Villejuif France; Centre d'Investigation Clinique BIOTHERIS, INSERM CIC1428, Villejuif, France; Radiologie Interventionnelle, Gustave Roussy, Villejuif, France; Laboratoire de Recherche Translationnelle en Immunothérapie (LRTI), INSERM U1015, Villejuif, France; Faculté de Médecine, Paris-Saclay Université, F-94276 Le Kremlin Bicêtre, France.

Purpose: To evaluate the feasibility and accuracy of a robotic device used clinically in soft tissues (abdomen and lung), modified in design and workflow, to perform needle insertion in percutaneous bone procedures.

Methods: The primary objective was safety (severe complications) of robotic-assisted insertion in this new application. Secondary objectives were feasibility (placement technical success), performance (acceptable insertions rate), accuracy (lateral deviation), number of intermediate CT-scans and tolerance (minor/moderate complications).

View Article and Find Full Text PDF

For almost two decades, dual antiplatelet therapy (DAPT) has been considered the cornerstone of pharmacological treatment in patients undergoing percutaneous coronary intervention (PCI). DAPT composition and duration have considerably evolved in the last decade moving from fixed treatment durations to tailored strategies based on the individual ischemic and bleeding risks. The increasing awareness of the prognostic relevance of bleeding events after PCI and the need for tailoring DAPT according to the individual bleeding and ischemic risks paved the way to newer DAPT modulation strategies by early aspirin withdrawal which have been shown to decrease bleeding without affecting therapeutic efficacy.

View Article and Find Full Text PDF

Introduction: This report describes the use of a combination of a retrograde femoral nail and distal femur locking plate for the treatment of an open intra-articular distal femur fracture in a 99-year-old female. The purpose of this report is to highlight that nail-plate fixation constructs can be performed percutaneously and expeditiously even in extremely old patients; therefore, patient age should not be a limiting factor in choosing this construct to allow for immediate weight-bearing.

Case Report: The patient was a 99-year-old female who presented to the emergency room after a fall.

View Article and Find Full Text PDF

Objectives: This study aimed to identify the barriers to and enablers of secondary prevention care and cardiac rehabilitation (CR) utilization by patients with coronary heart disease (CHD) following percutaneous coronary intervention (PCI) from the perspective of policymakers.

Methods: A qualitative study involving an interpretive descriptive design was conducted through recorded semistructured interviews with key decision-makers in cardiology care in Saudi Arabia. The analysis was guided by the updated Consolidated Framework for Implementation Research (CFIR), which informed the resulting themes.

View Article and Find Full Text PDF

A Case Report Describing the Surgical Removal of Venous and Intracardiac Cement Leakage after Percutaneous Vertebroplasty in a Hybrid Operating Room.

Ann Ital Chir

December 2024

Department of Cardiovascular Surgery, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy; Department of Biomedical, Surgical, and Dental Sciences, University of Milan, 20122 Milan, Italy.

Aim: Percutaneous vertebroplasty is generally considered a safe procedure, however, cases of cardioembolism and cardiac perforation have been reported.

Case Presentation: A 69-year-old woman was referred to our emergency department after an outpatient echocardiogram revealed a "thrombus-like" formation involving the right heart. Two weeks before she had undergone percutaneous vertebroplasty of the third to fifth lumbar vertebrae due to osteoporotic fractures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!