Early structural valve deterioration of Mitroflow aortic bioprosthesis: mode, incidence, and impact on outcome in a large cohort of patients.

Circulation

From the Department of Thoracic and Cardiovascular Surgery (T.S., S.P., M.M., A.M., C.P., H.F.C., O.A.H., O.B., J.C.R.), Institut du Thorax (T.S., T.L.T., S.P., C.C., M.M., A.M., C.P., H.F.C., O.A.H., O.B., J.C.R.), Department of Cardiology (T.L.T., C.C.), and Department of Radiology (J.S.), University Hospital, Nantes, France; Member of Translink European Network (dedicated to structural valve deterioration) (T.S., T.L.T., C.C., J.C.R.); INSERM UMR1087, Nantes, France (T.L.T.); and EA 4275 SPHERE (BioStatistics, Pharmacoepidemiology & Human SciEnces REsearch), University of Nantes, Nantes, France (T.S., Y.F.).

Published: December 2014

Background: Structural valve deterioration (SVD) is a major flaw of bioprostheses. Early SVD has been suspected in the last models of Mitroflow bioprosthesis. We sought to assess the incidence, mode, and impact of SVD on outcome in a large series of Mitroflow aortic valve replacement.

Methods And Results: Six hundred seventeen consecutive patients (aged 76.1±6.3 years) underwent aortic valve replacement with a Mitroflow prosthesis (models 12A/LX) between 2002 and 2007. By echocardiography, 39 patients developed early SVD (1.66% per patient-year), with stenosis as the main mode (n=36). Mean delay to SVD was only 3.8±1.4 years, and 5-year SVD-free survival was 91.6% (95% confidence interval [CI], 88.7-94.7) for the whole cohort and 79.8% (95% CI, 71.2-89.4) and 94.0% (95% CI, 90.3-97.8) for 19- and 21-mm sizes, respectively. Among the 39 patients with SVD, 13 patients (33%) had an accelerated SVD once the mean gradient exceeded 30 mm Hg. Valve-related death was 46.2% in this SVD subgroup. Five-year overall survival was 69.6% (95% CI, 65.7-73.9). In multivariable analysis, SVD was the strongest correlate of overall mortality (hazard ratio=7.7; 95% CI, 4.4-13.6).

Conclusions: Early SVD is frequent in Mitroflow bioprosthesis (models 12A/LX), especially for small sizes (19 and 21 mm), and reduces overall survival. An unpredictable accelerated pattern of SVD constitutes a life-threatening condition. In view of the large number of Mitroflow valves implanted worldwide, one can expect an epidemic of SVD and valve-related deaths, which represents a major public health issue, especially in the elderly. Hence, a close follow-up with yearly echocardiography after Mitroflow implantation is advisable. An urgent reoperation should be discussed in patients with severe SVD even though they are still asymptomatic.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.114.010400DOI Listing

Publication Analysis

Top Keywords

svd
13
early svd
12
structural valve
8
valve deterioration
8
mitroflow aortic
8
outcome large
8
mitroflow bioprosthesis
8
aortic valve
8
models 12a/lx
8
mitroflow
7

Similar Publications

Background: Coronary artery disease (CAD) comprises one of the leading causes of morbidity and mortality both in the European population and globally. All established clinical risk stratification scores and models require blood lipids and physical measurements. The latest reports of the European Commission suggest that attracting health professionals to collect these data can be challenging, both from a logistic and cost perspective, which limits the usefulness of established models and makes them unsuitable for population-wide screening in resource-limited settings, i.

View Article and Find Full Text PDF

Background: Drug-coated balloons (DCB) are emerging as an alternative to permanent implants for managing de novo coronary artery disease, particularly in small vessels (SVD). This sub-analysis of the PICCOLETO II study aimed to compare the performance of DCB and DES in terms of Murray's law-based quantitative flow ratio (μFR) changes between baseline, post-percutaneous coronary intervention (PCI), and follow-up.

Methods: Patients with a clinical indication for PCI were assigned to receive either Xience DES or Elutax SV/Emperor DCB.

View Article and Find Full Text PDF

Residents' Exposure to Obstetric Anal Sphincter Injury: A 16-Year Temporal Trend.

Urogynecology (Phila)

December 2024

Department of Obstetrics & Gynecology, ChristianaCare, Newark, DE.

Importance: Exposure to the surgical management of obstetric anal sphincter injuries (OASIS) is limited during obstetrics training.

Objectives: The objective of this study was to quantify residents' exposure to OASI repair during 4-year obstetrics and gynecology (OBGYN) residency and examine temporal trends over a 16-year period.

Study Design: This was a retrospective cohort study of residents' exposure to OASIS at a community academic hospital from 2007 to 2022.

View Article and Find Full Text PDF

Individual cerebral small vessel disease (SVD) markers independently predict poor prognosis following stroke. However, the impact of a single SVD, especially cumulative SVD burden on outcomes in acute ischemic stroke (AIS) after intravenous thrombolysis remains unclear. This work evaluated the occurrence of small vessel disease (SVD) in AIS patients who were treated with intravenous thrombolytic therapy by using multimodal MRI imaging.

View Article and Find Full Text PDF

Background: Cardiac monitoring strategies to detect occult atrial fibrillation (AF) post-stroke differ among healthcare institutions. This may be related to discrepancies in stroke subtype classification/adjudication, and/or consultation of cardiology specialists at Community Hospitals (CoH) and Academic Centers (AcC). Identifying the degree of heterogeneity may encourage development of guideline-directed monitoring protocols, result in higher AF detection rates and treatments, and fewer strokes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!