Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aims: Transient ST-T elevation (STE) is a rare complication that occurs during transseptal catheterization. This study aims to delineate the incidence and characteristics of transient STE during transseptal catheterization for atrial fibrillation (AF) ablation.
Methods And Results: Consecutive patients who underwent fluoroscopy-guided transseptal catheterization for circumferential pulmonary vein radiofrequency ablation in Beijing An Zhen Hospital from January 2006 to January 2013 were enrolled in this study. Out of 2965 patients with a total of 3452 transseptal catheterization procedures, 13 patients (0.38%, mean age 57 ± 8, 6 female, 12 paroxysmal AF, mean left atrial diameter 35.4 ± 3.8 mm) had STE. ST-T elevation occurred after transseptal puncture in 10 patients and after pulmonary vein venography in three patients. Systolic blood pressure (129 ± 10 vs. 104 ± 20 mmHg, P < 0.001), diastolic blood pressure (78 ± 6 vs. 64 ± 11 mmHg, P < 0.001), and heart rate (83 ± 19 bpm vs. 64 ± 23 b.p.m., P = 0.022) significantly decreased when STE occurred. Eleven patients complained of chest pain, one patient complained of dizziness, and one patient had no symptoms. Patients recovered in about 4.6 min (2-10 min) with dopamine or fast saline drip. Catheter ablation of AF was completed in all the 13 patients without sequelae or other complications. Four of the 13 patients (30.8%) had recurrence of AF after a mean follow-up of 21.7 months.
Conclusion: ST-T elevation is a rare complication associated with transseptal catheterization without sequelae. Catheter ablation of AF could be safely completed in these patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/europace/euu278 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!