Background: The 256-slice computed tomography (CT) scanners with wider detector coverage and faster gantry rotation speed are now available. The performance of scanners that feature a rotation speed of 270 ms at coronary CT angiography (CCTA) has not been evaluated in patients with a higher heart rate.
Purpose: To evaluate the image quality of 256-slice CT with faster gantry rotation speed in patients undergoing CCTA.
Material And Methods: We enrolled 886 patients; 357(40.3%) underwent study on a 64-slice CT at a rotation speed of 420 ms, the other 529 (59.7%) were examined using a 256-slice CT scanner at 270 ms. Two observers judged the image quality of 2658 imaged coronary arteries on a 4-point scale.
Results: The mean image quality score was significantly higher for the 256 - than the 64-slice CT scans (3.94 ± 0.28 vs. 3.73 ± 0.61; P < 0.01). There was no significant difference in the image quality scores between 64 - and 256-slice scans in patients whose heart rate (HR) was <60 bpm. However, in patients whose HR exceeded 60 bpm these scores were significantly higher for 256-slice CT images (P < 0.01).
Conclusion: CCTA performed on the 256-slice CT scanner yielded significantly better image quality in patients with an HR exceeding 60 bpm.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0284185114555152 | DOI Listing |
Sci Rep
December 2024
School of Chemistry, Faculty of Engineering and Physical Sciences, University of Southampton, Life Sciences Building 85, University Road, Highfield, Southampton, SO17 1BJ, UK.
Osteoarthritis (OA) is a complex disease of cartilage characterised by joint pain, functional limitation, and reduced quality of life with affected joint movement leading to pain and limited mobility. Current methods to diagnose OA are predominantly limited to X-ray, MRI and invasive joint fluid analysis, all of which lack chemical or molecular specificity and are limited to detection of the disease at later stages. A rapid minimally invasive and non-destructive approach to disease diagnosis is a critical unmet need.
View Article and Find Full Text PDFSci Rep
December 2024
Center for Drug Discovery, Graduate School of Pharmaceutical Sciences, University of Shizuoka, Suruga-ku, Shizuoka, 422-8526, Shizuoka, Japan.
The cell painting assay is useful for understanding cellular phenotypic changes and drug effects. To identify other aspects of well-known chemicals, we screened 258 compounds with the cell painting assay and focused on a mitochondrial punctate phenotype seen with disulfiram. To elucidate the reason for this punctate phenotype, we looked for clues by examining staining steps and gene knockdown as well as examining protein solubility and comparing cell lines.
View Article and Find Full Text PDFSci Rep
December 2024
College of Electrical Engineering, Northeast Electric Power University, Jilin, 132012, China.
The scattering of tiny particles in the atmosphere causes a haze effect on remote sensing images captured by satellites and similar devices, significantly disrupting subsequent image recognition and classification. A generative adversarial network named TRPC-GAN with texture recovery and physical constraints is proposed to mitigate this impact. This network not only effectively removes haze but also better preserves the texture information of the original remote sensing image, thereby enhancing the visual quality of the dehazed image.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Japan.
Cine-magnetic resonance imaging (MRI) has been used to track respiratory-induced motion of the liver and tumor and assist in the accurate delineation of tumor volume. Recent developments in compressed sensitivity encoding (SENSE; CS) have accelerated temporal resolution while maintaining contrast resolution. This study aimed to develop and assess hepatobiliary phase (HBP) cine-MRI scans using CS.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Artificial Intelligence Convergence, Chonnam National University, Gwangju, 61186, Republic of Korea.
Polarization-sensitive optical coherence tomography (PS-OCT) measures the polarization state of backscattered light from tissues and provides valuable insights into the birefringence properties of biological tissues. Contrastive unpaired translation (CUT) was used in this study to generate a synthetic PS-OCT image from a single OCT image. The challenges related to extensive data requirements relying on labeled datasets using only pixel-wise correlations that make it difficult to efficiently regenerate the periodic patterns observed in PS-OCT images were addressed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!