Unlabelled: Image-guided navigation (IGN) systems provide automation support of intra-operative information analysis and decision-making for surgeons. Previous research showed that navigated-control (NC) systems which represent high levels of decision-support and directly intervene in surgeons' workflow provide benefits with respect to patient safety and surgeons' physiological stress but also involve several cost effects (e.g. prolonged surgery duration, reduced secondary-task performance). It was hypothesised that less automated distance-control (DC) systems would provide a better solution in terms of human performance consequences. N = 18 surgeons performed a simulated mastoidectomy with NC, DC and without IGN assistance. Effects on surgical performance, physiological effort, workload and situation awareness (SA) were compared. As expected, DC technology had the same benefits as the NC system but also led to less unwanted side effects on surgery duration, subjective workload and SA. This suggests that IGN systems just providing information analysis support are overall more beneficial than higher automated decision-support.

Practitioner Summary: This study investigates human performance consequences of different concepts of IGN support for surgeons. Less automated DC systems turned out to provide advantages for patient safety and surgeons' stress similar to higher automated NC systems with, at the same time, reduced negative consequences on surgery time and subjective workload.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00140139.2014.970588DOI Listing

Publication Analysis

Top Keywords

image-guided navigation
8
support surgeons
8
ign systems
8
systems provide
8
patient safety
8
safety surgeons'
8
surgery duration
8
human performance
8
performance consequences
8
subjective workload
8

Similar Publications

Microscopic augmented reality calibration with contactless line-structured light registration for surgical navigation.

Med Biol Eng Comput

January 2025

Mechanical Engineering Department, Tianjin University, No. 135, Yaguan Road, Haihe Education Park, Jinnan District, Tianjin City, 300350, China.

The use of AR technology in image-guided neurosurgery enables visualization of lesions that are concealed deep within the brain. Accurate AR registration is required to precisely match virtual lesions with anatomical structures displayed under a microscope. The purpose of this work was to develop a real-time augmented surgical navigation system using contactless line-structured light registration, microscope calibration, and visible optical tracking.

View Article and Find Full Text PDF

Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.

View Article and Find Full Text PDF

Background: Hereditary Multiple Osteochondromas (HMO), previously known as Multiple Hereditary Exostoses (MHE), is a genetic disorder characterized by the formation of multiple, benign, exostoses (osteochondromas) growing from the metaphyseal region of long bones as well as from the axial skeleton. Lesions originating from the lumbar spine region are rare, and are most common growing from the posterior element of the vertebrae. HMO associated osteochondromas are difficult to treat due to continuous and incontrollable growth of these lesions and a lifetime risk for malignant transformation.

View Article and Find Full Text PDF

Objective: To maximize local tumor control, stabilize affected bones, and preserve or replace joints with minimal interventional burden, thereby enhancing quality of life for empowered living.

Indications: Suitable for patients with bone metastases, particularly those with severe pain and/or fractures and appropriate life expectancy.

Contraindications: In primary bone tumors, refer to the sarcoma surgery team for evaluation of wide resection.

View Article and Find Full Text PDF

Background: Targeted and systematic transperineal biopsy of lesions guided by magnetic resonance imaging (MRI) and transrectal ultrasonography (TRUS) fusion technique may optimize the biopsy procedure and enhance the detection of prostate cancer. We described the transperineal biopsy guided by an automatic MRI-TRUS fusion technique, and evaluated the accuracy and feasibility of this method in a prospective single-center study.

Methods: The proposed method focuses on automating the delineation of prostate contours in both the MRI and TRUS images, the registration and fusion of MRI and TRUS images, the generation and visualiztion of the systematic biopsy cores in their corresponding locations within the 2D and the 3D views, as well as the computation and visualiztion of needle trajectories from preoperative planning to intraoperative navigation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!