Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, walking time, transitions and step count for both legs in young people with hemiplegic and asymmetric diplegic CP. Seventeen participants with CP Gross Motor Function Classification System level I completed two video recorded test protocols that involved wearing an activPAL™ activity monitor on alternate legs. Agreement between observed video recorded data and activPAL™ activity monitor data was assessed using the Bland and Altman (BA) method and intraclass correlation coefficients (ICC 3,1). There was perfect agreement for transitions and high agreement for sitting (BA mean differences (MD): -1.8 and -1.8 s; ICCs: 0.49 and 0.95) standing (MD: 0.8 and 0.1 s; ICCs: 0.59 and 0.98) walking (MD: 1 and 1.1 s; ICCs: 0.99 and 0.94) timings and low agreement for step count (MD: 4.1 and 2.8 steps; ICCs: 0.96 and 0.95) for both legs. This study found clinically acceptable agreement with direct observation for all activPAL™ activity monitor functions, except for step count measurement with respect to the range of measurement values obtained for both legs in this study population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0967-3334/35/11/2307 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!