Purpose: To prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.
Materials And Methods: Hundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients' age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.
Results: Sixty-nine male and 31 female patients underwent antegrade puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm(2). Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.
Conclusion: Ultrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00270-014-0998-7 | DOI Listing |
Kidney Int Rep
October 2023
Division of Nephrology, Ulm University, Ulm, Germany.
Introduction: Radiographic fluoroscopy is the current standard for placement of tunneled central venous catheters (CVCs) for hemodialysis. Radiographic fluoroscopy requires structural and personnel infrastructure and exposes the patient to ionizing radiation. Here, we investigate the feasibility of solely ultrasound-guided placement of tunneled central venous dialysis catheters (USCVCs).
View Article and Find Full Text PDFClin J Pain
February 2023
Department of Pain, Beijing Xuanwu Hospital, Capital Medical University, Beijing, China.
Object: To estimate the contrast dispersion short-term clinical efficacy and safety of ultrasound (US)-guided transforaminal steroid injection (TFSI) compared with computed tomography (CT) guidance for the treatment of cervical radicular pain.
Method: A total of 430 patients with cervical radicular pain from cervical herniated disk or cervical spondylosis were recruited in the randomized, single-blind, controlled, noninferiority trial. The patients were randomly assigned to receive either the US-guided or CT-guided TFSI for 1 affected cervical nerve.
J Pain Res
October 2020
Department of Anesthesia and Pain Medicine, Beijing Chaoyang Hospital, Capital Medical University, Beijing 100020, People's Republic of China.
Background: Imaging-guided celiac plexus neurolysis using ultrasound (US) guidance via a transabdominal approach and endoscopic-ultrasound (EUS) has been increasingly applied for the treatment of pancreatic cancer-associated abdominal pain.
Objective: To investigate the application of ultrasound-guided and fluoroscopy-assisted celiac plexus neurolysis in a patient with advanced pancreatic cancer suffering from refractory abdominal pain for which oral opioid treatment was ineffective.
Case Report: We report a case of ultrasound-guided and fluoroscopy-assisted celiac plexus neurolysis in a patient with advanced pancreatic cancer with refractory abdominal pain.
Pacing Clin Electrophysiol
July 2020
Department of Surgery, Catholic University Hospital "A. Gemelli", Roma, Italy.
Background: The venous access for the insertion of permanent leads of cardiac implantable electronic devices is often achieved by venous cutdown of the cephalic vein, or by "blind" puncture of the subclavian vein using anatomical landmarks, or by fluoroscopy-assisted methods.
Methods: We have retrospectively analyzed our clinical experience to verify the feasibility, the safety, and efficacy of the adoption of ultrasound-guided puncture/cannulation of the axillary vein for this purpose.
Results: Nine hundred eighty-seven leads were placed during 548 consecutive procedures, accessing the axillary vein in the infraclavicular area using real-time ultrasound guidance.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!