The clinical value of serial measurement of high-sensitivity cardiac troponin T in acute exacerbations ofchronic obstructive pulmonary disease.

Open Heart

Division of Medicine , Akershus University Hospital , Lørenskog , Norway ; Institute of Clinical Medicine, University of Oslo, Oslo , Norway.

Published: January 2021

Objective: To assess the prevalence and long-term prognostic value of a dynamic (rise/fall) pattern of cardiac troponin T (hs-cTnT) elevation during acute exacerbation of chronic obstructive pulmonary disease (AECOPD) compared with a stable hs-cTnT elevation.

Methods: Prospective cohort study of unselected patients admitted with AECOPD to the emergency room of a university hospital. Serial hs-cTnT measurements were made during admission. Survival after a median of 1.8 years was recorded.

Results: 83 patients with a mean age of 72 years and a mean forced expiratory volume in 1 s (FEV1) of 0.9 L. The mortality rate was 62%. The median hs-cTnT at admission was 27 ng/L (IQR 13.4-51)). 65 patients (78%) had at least one hs-cTnT measurement ≥14 ng/L, and among these the median change in hs-cTnT was 50.7% (IQR 25.2-89.4). Of the patients with serial hs-cTnT measurements, 53 (82%) had a dynamic pattern (ie, ΔTnT ≥20%). In multivariate analysis, stable hs-cTnT elevation was associated with increasing age (OR per 5 years with 95% CI 1.9 (1.01 to 3.7), p=0.045) and low Hb (OR 7.3 (1.1 to 49), p=0.039). Stable hs-cTnT elevation was associated with increased mortality with an HR of 2.4 (95%CI 1.1 to 5.3, p=0.027) in the multivariate Cox regression analysis.

Conclusions: Among the patients with at least one hs-cTnT above the 99th centile, 82% had a rise/fall pattern, as requested to make a diagnosis of myocardial infarction. Compared to a dynamic rise/fall pattern of hs-cTnT, a stable and moderately elevated hs-cTnT during AECOPD is associated with poor long-term prognosis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4189317PMC
http://dx.doi.org/10.1136/openhrt-2013-000001DOI Listing

Publication Analysis

Top Keywords

rise/fall pattern
12
hs-ctnt
12
hs-ctnt elevation
12
stable hs-ctnt
12
cardiac troponin
8
obstructive pulmonary
8
pulmonary disease
8
dynamic rise/fall
8
serial hs-ctnt
8
hs-ctnt measurements
8

Similar Publications

Background: The COVID pandemic accelerated the adoption of telehealth. Long-term implications for continued telehealth use on a large scale in primary care are still emerging, and the key to this understanding is how telehealth adoption impacts the delivery of health care.

Objectives: Our objective was to quantify how telehealth adoption during the pandemic impacted patients' access to healthcare and the usage patterns of different access modalities (in-office, audio, and video).

View Article and Find Full Text PDF

A fast 2D MoS photodetector with ultralow contact resistance.

Nanoscale

November 2024

School of Electronic Science and Engineering, Nanjing University, Nanjing 210093, China.

Two-dimensional (2D) transition metal dichalcogenides (TMDs), such as molybdenum disulfide (MoS), hold great promise for next-generation nanoelectronic and nanophotonic devices. While high photoresponsivity and broad spectral coverage (UV-IR) have been reported, the slow response time of MoS photodetectors caused by their unfavorable RC characteristics is still a major limit in current devices. Once the RC limit issue is resolved, the intrinsic saturation drift velocity of electrons in TMDs (∼10 cm s) may enable GHz opto-electronic operations.

View Article and Find Full Text PDF
Article Synopsis
  • * In a study of 3789 AIS patients, 300 had cTn measurements; those with a rising pattern had a significantly higher risk of 7-day mortality and unfavorable discharge compared to those with falling or stable levels.
  • * The findings suggest that monitoring cTn patterns in AIS patients can help predict mortality risk and guide clinical decision-making.
View Article and Find Full Text PDF

Study Objective: To evaluate the effect of continuing of angiotensin-converting enzyme inhibitor (ACEI) or angiotensin II receptor blocker (ARB) prescriptions 24 h before surgery on postoperative myocardial injury and blood pressure in patients undergoing non-cardiac surgery.

Design: A single-center, retrospective study.

Setting: Operating room and perioperative care area.

View Article and Find Full Text PDF

From the perspective of the innovation value chain, this study divides the innovation efficiency of green technology into two stages: R&D efficiency and achievement transformation efficiency. Technology density is introduced as a threshold variable to examine the influence of environmental regulation on the efficiency of green technology innovation at both stages. The findings reveal that China's overall green technology innovation efficiency (GTIE) is improving.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!