We describe an algorithm for designing the equilibrium base-pairing properties of a test tube of interacting nucleic acid strands. A target test tube is specified as a set of desired "on-target" complexes, each with a target secondary structure and target concentration, and a set of undesired "off-target" complexes, each with vanishing target concentration. Sequence design is performed by optimizing the test tube ensemble defect, corresponding to the concentration of incorrectly paired nucleotides at equilibrium evaluated over the ensemble of the test tube. To reduce the computational cost of accepting or rejecting mutations to a random initial sequence, the structural ensemble of each on-target complex is hierarchically decomposed into a tree of conditional subensembles, yielding a forest of decomposition trees. Candidate sequences are evaluated efficiently at the leaf level of the decomposition forest by estimating the test tube ensemble defect from conditional physical properties calculated over the leaf subensembles. As optimized subsequences are merged toward the root level of the forest, any emergent defects are eliminated via ensemble redecomposition and sequence reoptimization. After successfully merging subsequences to the root level, the exact test tube ensemble defect is calculated for the first time, explicitly checking for the effect of the previously neglected off-target complexes. Any off-target complexes that form at appreciable concentration are hierarchically decomposed, added to the decomposition forest, and actively destabilized during subsequent forest reoptimization. For target test tubes representative of design challenges in the molecular programming and synthetic biology communities, our test tube design algorithm typically succeeds in achieving a normalized test tube ensemble defect ≤1% at a design cost within an order of magnitude of the cost of test tube analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/sb5002196 | DOI Listing |
Pak J Med Sci
January 2025
Ruichao Miao Department of Reproductive Center, Qingdao Women and Children's Hospital, Qingdao, Shandong Province 266000, P.R. China.
Objective: To assess and compare efficacy of 4-dimensional hysterosalpingo-contrast sonography (4D-HyCoSy) and X-ray hysterosalpingography (HSG) for fallopian tube examination.
Methods: Clinical data of patients with suspected tubal infertility, who underwent examinations in Qingdao Women and Children's Hospital from September 2021 to December 2023, were retrospectively analyzed. Of them, 40 patients received laparoscopy and dye test+ 4D-HyCoSy (4D-HyCoSy group), and 36 patients received laparoscopy and dye test +HSG (HSG group).
Background: Identification of young children with ( )-infection is critical to curb Tuberculosis (TB)-related pediatric morbidity and mortality. The optimal test to identify young children with evidence of -infection remains controversial.
Methods: Using a TB household contact (HHC) study design among 130 Ugandan children less than 5 years with established -exposure, we compared the usefulness of the tuberculin skin test (TST) and QuantiFERON Gold Plus (QFT-Plus) to identify children with evidence for -sensitization.
Int J Nanomedicine
January 2025
Shanghai Eighth People's Hospital, Xuhui District, Shanghai, 200030, People's Republic of China.
Purpose: Gastrostomy is the commonly used enteral feeding technology. The clinical risks caused by tube dislodgement and peristomal site infection are the common complications before complete tract maturation after gastrostomy. However, there is currently no relevant research to promote gastrostomy wound treatment and tract maturation.
View Article and Find Full Text PDFJ Med Imaging (Bellingham)
January 2025
U.S. Food and Drug Administration, Office of Science and Engineering Labs, Division of Imaging, Diagnostics, and Software Reliability, Silver Spring, Maryland, United States.
Purpose: We evaluate the impact of charge summing correction on a cadmium telluride (CdTe)-based photon-counting detector in breast computed tomography (CT).
Approach: We employ a custom-built laboratory benchtop system using the X-THOR FX30 0.75-mm CdTe detector (Varex Imaging, Salt Lake City, Utah, United States) with a pixel pitch of 0.
Anal Chem
January 2025
Department of Biomolecular Chemistry, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
Peptide ion mobility adds an extra dimension of separation to mass spectrometry-based proteomics. The ability to accurately predict peptide ion mobility would be useful to expedite assay development and to discriminate true answers in a database search. There are methods to accurately predict peptide ion mobility through drift tube devices, but methods to predict mobility through high-field asymmetric waveform ion mobility (FAIMS) are underexplored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!