Background: The medial patellofemoral ligament (MPFL) is essential for the maintenance of correct biomechanical function of the knee. Reconstruction of the MPFL is commonly used in the restoration of patellofemoral stability after traumatic lateral subluxation of the patella. Although a method to accurately determine the MPFL's insertion point has been described, it remains unclear if anatomic placement of MPFL graft tissue is essential for preservation of knee function after MPFL reconstruction. Thus, the purpose of this study was to determine the importance of anatomic placement of MPFL graft tissue for the preservation of knee function following MPFL reconstruction operations.
Methods: Twenty-seven subjects who underwent MPFL reconstruction operations were retrospectively analyzed. Postoperative radiographs were reviewed. Measurements were taken, and the placement of each patient's MPFL graft tissue was determined to be anatomic or non-anatomic based on radiographic methods previously described in the literature. Each subject's electronic medical record was then reviewed, and clinical data was recorded. Finally, the clinical outcomes of each patient were compared to placement location of the MPFL graft tissue in their procedure.
Results: Thirteen patients were found to have anatomic MPFL graft tissue placement, and 14 non-anatomic. A significant post-operative difference was found between groups in the following parameters: WOMAC pain (anatomic mean = 85.71 ± 11.34, non-anatomic mean = 75.00 ± 26.35 p = 0.018), function (anatomic mean = 85.85 ± 9.96, non-anatomic mean = 79.09 ± 24.45, p = 0.017) and in KOOS symptom (anatomic mean = 75.63 ± 11.79, non-anatomic mean = 67.83 ± 22.40, p = 0.024), pain (anatomic mean = 77.54 ± 8.61, non-anatomic mean = 71.39 ± 25.18, p = 0.01), ADL (anatomic mean = 85.85 ± 9.97, non-anatomic mean = 79.09 ± 24.45, p = 0.017) and overall (anatomic mean = 74.61 ± 10.33, non-anatomic mean = 69.41 ± 24.25, p = 0.01) scores. No significant difference was observed for post-op instability (p = 0.290) or apprehension (p = 0.496), improvement in WOMAC or KOOS, 2-week, 6-week, or final 1-year range of motion, WOMAC stiffness, or KOOS sport/recreation or QOL.
Conclusion: Within the range of graft placement values considered by this study, while no reduction in range of motion was seen, non-anatomic placement of MPFL graft tissue in MPFL reconstruction operations caused increased pain and decreased function, evidenced by post-operative KOOS and WOMAC scores.
Clinical Relevance: It seems that the pivotal step in MPFL reconstruction operations is ensuring correct patellofemoral tracking via intraoperative electrical femoral nerve stimulation. If this step of the procedure is performed correctly, non-anatomic placement will not limit range of motion, lead to continued apprehension, or affect the overall biomechanical functioning of the knee.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4127708 | PMC |
Foot Ankle Int
January 2025
Department of Orthopaedic Surgery, Chungbuk National University Hospital, Cheongju, Republic of Korea.
Background: Autologous osteochondral transplantation (AOT) is an option to treat large osteochondral lesions of the talus (OLTs), accompanying subchondral cyst, and previous unsuccessful bone marrow stimulation (BMS) procedures. Although there is extensive literature on the outcomes of surgical interventions for medial osteochondral lesions, research focusing on lateral lesions remains limited. This article presents the intermediate-term clinical and radiologic outcomes following AOT for lateral OLTs.
View Article and Find Full Text PDFXenotransplantation
January 2025
Beijing Key Laboratory of Preclinical Research and Evaluation for Cardiovascular Implant Materials, Animal Experimental Centre, National Centre for Cardiovascular Disease, Department of Cardiac Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Organ transplants are used to treat many end-stage diseases, but a shortage of donors means many patients cannot be treated. Xenogeneic organs have become an important part of filling the donor gap. Many current studies of kidney, heart, and liver xenotransplantation have used gene-edited pig organs on brain-dead recipients.
View Article and Find Full Text PDFXenotransplantation
January 2025
Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland, USA.
Advancements in xenotransplantation intersecting with modern machine perfusion technology offer promising solutions to patients with liver failure providing a valuable bridge to transplantation and extending graft viability beyond current limitations. Patients facing acute or acute chronic liver failure, post-hepatectomy liver failure, or fulminant hepatic failure often require urgent liver transplants which are severely limited by organ shortage, emphasizing the importance of effective bridging approaches. Machine perfusion is now increasingly used to test and use genetically engineered porcine livers in translational studies, addressing the limitations and costs of non-human primate models.
View Article and Find Full Text PDFXenotransplantation
January 2025
Institute of Organ Transplantation, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Background: Gene-edited pigs for xenotransplantation usually contain one or more transgenes encoding human complement regulatory proteins (CRPs). Because of species differences, human CRP(s) expressed in gene-edited pigs may have difficulty inhibiting the activation of exogenous rabbit complement added to a complement-dependent cytotoxicity (CDC) assay. The use of human complement instead of rabbit complement in CDC experiments may more accurately reflect the actual regulatory activity of human CRP(s).
View Article and Find Full Text PDFUpdates Surg
January 2025
Department of Medical Biotechnology and Translational Medicine, University of Milan, Milan, Italy.
Background: Recently, several devices exploiting the near-infrared autofluorescence (NIR-AF) of parathyroid glands (PGs) have been developed. Nevertheless, their impact on both preserving PGs from inadvertent surgical dissection and on post-surgical hypoparathyroidism (hypoPTH) is controversial.
Methods: A retrospective study of 845 patients undergoing thyroid surgery in 2 academic tertiary centres was conducted.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!