Background And Purpose: To determine the correlation between the cross-sectional area (CSA) of the median nerve measured at the wrist using three-dimensional (3D) ultrasonography (US) and the electrophysiological severity of carpal tunnel syndrome (CTS).

Methods: We prospectively examined 102 wrists of 51 patients with clinical CTS, which were classified into 3 groups according to the electrodiagnostic (EDX) findings. Median nerve CSAs were measured using 3D US at the carpal tunnel inlet and at the level of maximal swelling.

Results: Ten wrists were negative for CTS. Of the 92 CTS-positive wrists, 23, 30, and 39 were classified as having mild, moderate, and severe CTS, respectively. The median nerve CSA differed significantly between the severe- and moderate-CTS groups (p=0.0007 at the carpal tunnel inlet and p<0.0001 at the maximal swelling site). There was a correlation between median nerve CSA and EDX parameters among those wrists with severe and mild CTS (p<0.0001 at both sites).

Conclusions: The median nerve CSA as measured by 3D US could provide additional information about the severity of CTS, as indicated by the strong correlation with standard EDX findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4198717PMC
http://dx.doi.org/10.3988/jcn.2014.10.4.348DOI Listing

Publication Analysis

Top Keywords

carpal tunnel
16
median nerve
12
severity carpal
8
tunnel syndrome
8
tunnel inlet
8
correlation ultrasonography
4
ultrasonography findings
4
findings electrodiagnostic
4
electrodiagnostic severity
4
carpal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!