While the theory of compressive sensing has been very well investigated in the literature, comparatively little attention has been given to the issues that arise when compressive measurements are made in hardware. For instance, compressive measurements are always corrupted by detector noise. Further, the number of photons available is the same whether a conventional image is sensed or multiple coded measurements are made in the same interval of time. Thus it is essential that the effects of noise and the constraint on the number of photons must be taken into account in the analysis, design, and implementation of a compressive imager. In this paper, we present a methodology for designing a set of measurement kernels (or masks) that satisfy the photon constraint and are optimum for making measurements that minimize the reconstruction error in the presence of noise. Our approach finds the masks one at a time, by determining the vector that yields the best possible measurement for reducing the reconstruction error. The subspace represented by the optimized mask is removed from the signal space, and the process is repeated to find the next best measurement. Results of simulations are presented that show that the optimum masks always outperform reconstructions based on traditional feature measurements (such as principle components), and are also better than the conventional images in high noise conditions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.53.006108 | DOI Listing |
Medical device-related pressure injuries (MDRPIs) pose a significant risk in the home health environment, where patients may lack continuous professional oversight. Devices commonly used in the home environment with the potential to cause a MDRPI include but are not limited to nasogastric tubes, feeding tubes, nasal cannulas, nasal cannula prongs, airway pressure masks, indwelling urinary catheters, sequential compression devices, dressings, bandages, and tracheostomies. When a medical device is used for an extended period, it can lead to unrelieved pressure or edema, cause friction and/or shearing that impairs sensation, reduces circulation, and alters the microclimate.
View Article and Find Full Text PDFACS Nano
January 2025
School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Republic of Singapore.
Hydrogel-based sensors have been widely studied for perceiving the environment. However, the simplest type of resistive sensors still lacks sensitivity to localized strain and other extractable data. Enhancing their sensitivity and expanding their functionality to perceive multiple stimuli simultaneously are highly beneficial yet require optimal material design and proper testing methods.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA.
Quantitative abdominal magnetic resonance imaging (MRI) offers non-invasive, objective assessment of diseases in the liver, pancreas, and other organs and is increasingly being used in the pediatric population. Certain quantitative MRI techniques, such as liver proton density fat fraction (PDFF), R2* mapping, and MR elastography, are already in wide clinical use. Other techniques, such as liver T1 mapping and pancreas quantitative imaging methods, are emerging and show promise for enhancing diagnostic sensitivity and treatment monitoring.
View Article and Find Full Text PDFBackground: Quadrilateral space syndrome is a painful disorder of the shoulder caused by static or dynamic entrapment of the axillary nerve and the posterior humeral circumflex artery. It was first described in 1983; however, it is an uncommon syndrome that initially presents with nonspecific shoulder pain or selective deltoid atrophy, and diagnosis is often delayed owing to its rarity. Young athletes of overhead sports are more commonly affected by this syndrome.
View Article and Find Full Text PDFBrain Behav
January 2025
University Clinic and Outpatient Clinic for Neurology, Martin-Luther-University Halle-Wittenberg, Halle/Saale, Germany.
Background: The aim of this review is to synthesize the existing knowledge regarding headaches attributed to external physical stimuli, as classified by the ICHD-3 (Group 4.6). Two forms can be distinguished in this group: (1) headache attributed to external compression and (2) headache attributed to external traction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!