A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improvement of the performance of targeted LC-MS assays through enrichment of histidine-containing peptides. | LitMetric

Mass spectrometric-based quantification using targeted methods has matured during the past decade and is now commonly used in proteomics. However, the reliability of protein quantification in complex matrixes using selected reaction monitoring is often impaired by interfering signals arising from coelution of nontargeted components. Sample preparation methods resulting in the reduction of the number of peptides present in the mixture minimizes this effect. One solution consists in the selective capture of peptides containing infrequent amino acids. The enrichment of histidine-containing peptides via immobilized metal-ion affinity chromatography loaded with Cu(2+) ions (IMAC-Cu) was applied in a quantitative workflow and found to be a simple and cost effective method for the reduction of sample complexity with high recovery and selectivity. When applied to a series of depleted human plasma digests, the method decreased nonspecific signals, resulting in a more precise and robust protein quantification. The method was also shown to be an alternative to HSA/IgG depletion during plasma protein analysis. This method, used in conjunction with recent improvements in the instrument's peak capacity, addresses a bottleneck generally encountered in quantitative proteomics studies by providing the robustness and throughput required for the analysis of large sample series without compromising the number of proteins monitored.

Download full-text PDF

Source
http://dx.doi.org/10.1021/pr5008152DOI Listing

Publication Analysis

Top Keywords

enrichment histidine-containing
8
histidine-containing peptides
8
protein quantification
8
improvement performance
4
performance targeted
4
targeted lc-ms
4
lc-ms assays
4
assays enrichment
4
peptides
4
peptides mass
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!