Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We constructed a double-modulation, reflection-type terahertz (THz) ellipsometer for precise measurement of the thickness of a paint film which is coated on a metal surface and which is not transparent to visible or mid-infrared light. The double-modulation technique enabled us to directly obtain two ellipsometric parameters, Δ(ω) and Ψ(ω), as a function of angular frequency, ω, with a single measurement while reducing flicker noise due to a pump laser. The bias voltage of a photoconductive antenna (PCA) used as a THz pulse emitter was modulated at 100 kHz, and a first lock-in amplifier (LA1) was connected to the output of an electro-optic (EO) signal-sampling unit. In addition, a wire-grid polarizer (WGP) was rotated at 100 Hz to conduct polarization modulation with a frequency of 200 Hz. The output signal from LA1 was fed into a second lock-in amplifier (LA2) that worked in synchronization with the rotating WGP (RWGP). By operating LA2 in a quadrature phase-detection mode, we were able to obtain in-phase and out-of-phase signals simultaneously, from which the two ellipsometric parameters for an isotropic sample could be derived at the same time while cancelling common-mode noise. The lower detection limit of the thickness measurement and the relative standard deviation (RSD) of a black paint film coated on an aluminum substrate were 4.3 µm and 1.4%, respectively. The possibility of determining all elements of the Jones matrix for an anisotropic material is also discussed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.22.020595 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!