Unlabelled: The aim of the study was to evaluate the efficacy of the buccal fat pad (BFP) in the reconstruction of various intraoral maxillary defects as well as the success, anatomy, healing process, merits, demerits, and complications of this technique.
Materials And Methods: The study was conducted in the Oral and Maxillofacial Surgery Department of the First Affiliated Hospital of of Xinjiang Medical University, China, between 2007 and 2013. The BFP was used as a pedicled graft in the reconstruction of small to medium-sized intraoral defects in patients (18 men and 9 women) ranging in age from 2 to 70 years (mean age, 36 y). The criterion taken for successful graft reconstruction was the complete epithelialization of the graft or complete closure of the perforation.
Results: All 27 intraoral maxillary defect patients were adequately repaired. After surgery, all patients had a favorable wound healing in their first month of follow-up. The surface changed from the typical fatty yellow to a pale yellow-white color after 3 to 4 days, and all fatty surfaces were covered by newly formed reepithelized mucosa in 3 to 4 weeks. The mouth opening and graft was also satisfactory in 7 patients who received adjuvant radiotherapy for carcinoma. So, we conclude that the use of BFP in intraoral maxillary defects is a clinically effective, convenient, safe, and quick method of repair for small to medium-sized defects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000001075 | DOI Listing |
J Dent
January 2025
Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University; Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Disease, College of Stomatology, Xi'an Jiaotong University; Department of Implant Dentistry, College of Stomatology, Xi'an Jiaotong University. Electronic address:
Objective: The study aimed to evaluate the accuracy and safety of the semi-active robotic system for implant placement in atrophic posterior maxilla.
Methods: Patients underwent robot-assisted implant placement in atrophic posterior maxilla were identified and included. Cone-beam computed tomography (CBCT) was performed before surgery.
J Contemp Dent Pract
October 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, Ibn Al-Nafis University for Medical Sciences, Sana'a, Yemen, Phone: +86 18682960907, e-mail: Orcid: https://orcid.org/0000-0002-6906-8279.
Aim: This study aimed to analyze the upper airway dimensions in adult patients with different anteroposterior (sagittal) skeletal malocclusions (class I, II, and III) using cone beam computed tomography (CBCT) imaging.
Materials And Methods: This retrospective cross-sectional study involved 90 CBCT records from adult subjects who were categorized into three skeletal groups based on their ANB values: Class I ( = 30), class II ( = 30), and class III ( = 30) and were evaluated. The following upper airway measurements were considered: oropharyngeal airway volume, hypopharyngeal airway volume, pharyngeal airway volume, oropharyngeal airway length, hypopharyngeal airway length, pharyngeal airway length, the most constricted site of the pharyngeal airway, and the most constricted cross-sectional area (MIN-CSA) of the pharyngeal airway.
J Dent Sci
January 2025
School of Dental Technology, College of Oral Medicine, Taipei Medical University, Taipei, Taiwan.
Background/purpose: The performance of intraoral scanners (IOSs) relies on the operator's skills. However, whether operator experience influences IOS accuracy remains unclear. This study investigated the effect of operator experience on the trueness accuracy and time-based efficiency of IOSs.
View Article and Find Full Text PDFAim: This study investigated the accuracy of intraoral scanner (IOS) based on different image acquisition technologies in the field of presurgical-orthopedictreatment (PSOT) in neonates with cleft.
Methods: Dental cast models of clinical situations representing unilateral cleft-lip-palate(UCLP), bilateral cleft-lippalate( BCLP) and cleft-palate(CP) with reference PEEK-scanbodies (Cares RC Mono-Scankörper, Straumann, Switzerland) were scanned utilizing four IOS systems: CareStream-CS3600®(CS), Medit-i500®(MD), Cerec-Omnicam®(SO), 3Shape-Trios-3®(TS). One calibrated operator made 5 scans from each model using each IOS (N=60).
Int J Comput Dent
January 2025
Purpose: The purpose of the study was to investigate the accuracy of complete-arch intraoral scans for all-on-4 implant treatment under simulated intraoral variables.
Materials And Methods: A maxillary model designed to receive 4 implants in the regions of first molars and canines was used. Intraoral digital scans were completed in a simulation device by simulating two2 different clinical conditions: normal intraoral variables (NIV) and limited intraoral variables (LIV).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!