AI Article Synopsis

  • Constitutive activation of EGFR is common in epithelial cancers, particularly NSCLC, and mutations affecting EGFR can guide targeted treatments, but traditional detection methods are invasive and costly.
  • Development of a new technology called EFIRM enables non-invasive, real-time detection of EGFR mutations in bodily fluids, such as saliva and plasma, using an electrochemical sensor.
  • EFIRM demonstrated high accuracy in detecting EGFR mutations in clinical tests, showing great potential as an effective and affordable alternative for monitoring NSCLC patients, termed SABER.

Article Abstract

Rationale: Constitutive activation of the epidermal growth factor receptor (EGFR) is prevalent in epithelial cancers, particularly in non-small cell lung carcinoma (NSCLC). Mutations identified in EGFR predict the sensitivity to EGFR-targeted therapy. Detection of these mutations is mainly based on tissue biopsy, which is invasive, expensive, and time consuming.

Objectives: Noninvasive, real-time, inexpensive detection and monitoring of EGFR mutations in patients with NSCLC is highly desirable.

Methods: We developed a novel core technology, electric field-induced release and measurement (EFIRM), which relies on a multiplexible electrochemical sensor that can detect EGFR mutations directly in bodily fluids.

Measurements And Main Results: We established EFIRM for the detection of the EGFR mutations in vitro and correlated the results with tumor size from xenografted mice. In clinical application, we demonstrated that EFIRM could detect EGFR mutations in the saliva and plasma of 22 patients with NSCLC. Finally, a blinded test was performed on saliva samples from 40 patients with NSCLC. The receiver operating characteristic analysis indicated that EFIRM detected the exon 19 deletion with an area under the curve of 0.94 and the L858R mutation with an area under the curve of 0.96.

Conclusions: Our data indicate that EFIRM is effective, accurate, rapid, user-friendly, and cost effective for the detection of EGFR mutations in the saliva of patients with NSCLC. We termed this saliva-based EGFR mutation detection (SABER).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5447327PMC
http://dx.doi.org/10.1164/rccm.201406-1003OCDOI Listing

Publication Analysis

Top Keywords

egfr mutations
20
patients nsclc
16
egfr
9
saliva-based egfr
8
mutation detection
8
detect egfr
8
detection egfr
8
mutations saliva
8
area curve
8
mutations
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!