A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Standardization of disk diffusion and agar dilution susceptibility tests for Neisseria gonorrhoeae: interpretive criteria and quality control guidelines for ceftriaxone, penicillin, spectinomycin, and tetracycline. | LitMetric

A six-laboratory study developed a standardized method for determining the susceptibilities of Neisseria gonorrhoeae strains to penicillin, tetracycline, spectinomycin, and ceftriaxone. Three quality control organisms were also selected, and quality assurance guidelines were initially generated for the disk diffusion and agar dilution methods. The medium recommended for gonococcal susceptibility testing was GC agar with a defined "XV-like" supplement. The supplement should be free of cysteine, a component implicated in the inactivation of some newer beta-lactam compounds. Penicillin, tetracycline, spectinomycin, and ceftriaxone were stable in agar plates stored at 3 to 5 degrees C for at least 2 weeks. Numerous GC agar and drug disk lots were used during the trials without significant variation in test results. Several other gonococcal strains were recommended for additional medium quality assurance. The disk quality control zone limits were established for N. gonorrhoeae ATCC 49226 (formerly CDC F-18) and Staphylococcus aureus ATCC 25923. MIC quality control ranges were also developed for N. gonorrhoeae ATCC 49226 and S. aureus ATCC 29213. The interpretive criteria for penicillin were as follows: susceptibility, greater than or equal to 47 mm (diameter of inhibition zone) (less than or equal to 0.06 micrograms/ml [MIC]); resistance, less than or equal to 26 mm (greater than or equal to 2 micrograms/ml). For tetracycline they were as follows: susceptibility, greater than or equal to 38 mm (less than or equal to 0.25 microgram/ml); resistance, less than or equal to 30 mm (greater than or equal to 2 micrograms/ml). For spectinomycin they were as follows: susceptibility, >/= 18 mm (/= 128 micrograms/ml). For ceftriaxone susceptibility, the criterion was >/= 35 mm (

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC267122PMC
http://dx.doi.org/10.1128/jcm.27.12.2758-2766.1989DOI Listing

Publication Analysis

Top Keywords

quality control
16
greater equal
16
disk diffusion
8
diffusion agar
8
agar dilution
8
neisseria gonorrhoeae
8
interpretive criteria
8
penicillin tetracycline
8
tetracycline spectinomycin
8
spectinomycin ceftriaxone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!