Purpose: Retinal densitometry provides objective information about retinal function. But, a number of factors, including retinal reflectance changes that are not directly related to photopigment depletion, complicate its interpretation. We explore these factors and suggest a method to minimize their impact.
Methods: An adaptive optics scanning light ophthalmoscope (AOSLO) was used to measure changes in photoreceptor reflectance in monkeys before and after photopigment bleaching with 514-nm light. Reflectance measurements at 514 nm and 794 nm were recorded simultaneously. Several methods of normalization to extract the apparent optical density of the photopigment were compared.
Results: We identified stimulus-related fluctuations in 794-nm reflectance that are not associated with photopigment absorptance and occur in both rods and cones. These changes had a magnitude approaching those associated directly with pigment depletion, precluding the use of infrared reflectance for normalization. We used a spatial normalization method instead, which avoided the fluctuations in the near infrared, as well as a confocal AOSLO designed to minimize light from layers other than the receptors. However, these methods produced a surprisingly low estimate of the apparent rhodopsin density (animal 1: 0.073 ± 0.006, animal 2: 0.032 ± 0.003).
Conclusions: These results confirm earlier observations that changes in photopigment absorption are not the only source of retinal reflectance change during dark adaptation. It appears that the stray light that has historically reduced the apparent density of cone photopigment in retinal densitometry arises predominantly from layers near the photoreceptors themselves. Despite these complications, this method provides a valuable, objective measure of retinal function.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4244068 | PMC |
http://dx.doi.org/10.1167/iovs.13-13795 | DOI Listing |
BMJ Open Ophthalmol
July 2024
Queen's University Belfast, Belfast, UK
Objective: Current literature reveals an association between anthropometric measures of adiposity (AnthM) and age-related macular degeneration (AMD), but few have explored the disease association with imaging methods. This study aimed to explore the relationship between AMD status and dual-energy X-ray absorptiometry measures (DEXAMs) among a representative sample of the US population, and compare the association with AnthM.
Method: Using a representative sample in the National Health and Nutrition Examination Study 2005-2006 (n=1632), DEXAMs across the whole body and waist (ie, android), and relative fat distributions (eg, percentage fat, android-to-total body ratio) were analysed between no AMD (baseline) and any AMD.
Clin Ophthalmol
May 2024
Department of Ophthalmology, University Hospital Carl Gustav Carus, TU Dresden, Dresden, 01307, Germany.
Purpose: Diabetes mellitus (DM) causes different corneal changes that are associated with the severity of diabetic retinopathy. To identify the pathophysiological reasons for this, corneal tomography and optical densitometry (COD) were combined with retinal oximetry.
Methods: Patients with DM and healthy subjects were included in this pilot study.
Ophthalmic Physiol Opt
July 2024
School of Optometry and Vision Sciences, Cardiff University, Cardiff, UK.
Purpose: The Beer-Lambert law suggests that visual pigment optical density (OD) should be linearly related to the length of photoreceptor outer segments (POSs). Mammalian studies indicate that visual pigment concentration increases with POS length, but the nature of this relationship may vary due to factors such as visual pigment packing density or retinal eccentricity, and may not necessarily be linearly related. The purpose of this study was to establish the relationship between OD and POS length in humans.
View Article and Find Full Text PDFActa Ophthalmol
May 2024
Department of Ophthalmology, Rigshospitalet Glostrup, Copenhagen, Denmark.
Purpose: To evaluate a new automated retinal oximetry image quality indicator with cataract as a clinical model.
Methods: Sixty-one eyes in 61 patients were imaged by the Oxymap T1 Retinal Oximeter at baseline and 25 eyes were also examined 3 weeks after cataract surgery. Image quality (0-10 on a continuous scale) was compared with standardized AREDS cataract grading and Pentacam lens densitometry.
Ther Adv Ophthalmol
July 2023
Ophthalmology Department, Pamukkale University, Denizli, Turkey.
Background: The mechanism of argon laser retinal photocoagulation (ALRP) treatment is to apply thermal-induced retinal pigment epithelium damage. Light passes through the anterior optical segments of the eye to reach the retina. Lens densitometry is a noninvasive and quantitative measurement providing information about corneal and lens clarity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!