Toward real-time automated detection of turns during gait using wearable inertial measurement units.

Sensors (Basel)

Laboratory of Robotics, University of Ljubljana, Tržaška cesta 25, SI-1000 Ljubljana, Slovenia.

Published: October 2014

Previous studies have presented algorithms for detection of turns during gait using wearable sensors, but those algorithms were not built for real-time use. This paper therefore investigates the optimal approach for real-time detection of planned turns during gait using wearable inertial measurement units. Several different sensor positions (head, back and legs) and three different detection criteria (orientation, angular velocity and both) are compared with regard to their ability to correctly detect turn onset. Furthermore, the different sensor positions are compared with regard to their ability to predict the turn direction and amplitude. The evaluation was performed on ten healthy subjects who performed left/right turns at three amplitudes (22, 45 and 90 degrees). Results showed that turn onset can be most accurately detected with sensors on the back and using a combination of orientation and angular velocity. The same setup also gives the best prediction of turn direction and amplitude. Preliminary measurements with a single amputee were also performed and highlighted important differences such as slower turning that need to be taken into account.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4239865PMC
http://dx.doi.org/10.3390/s141018800DOI Listing

Publication Analysis

Top Keywords

turns gait
12
gait wearable
12
detection turns
8
wearable inertial
8
inertial measurement
8
measurement units
8
sensor positions
8
orientation angular
8
angular velocity
8
compared regard
8

Similar Publications

Objectives: This study aims to objectively evaluate turning gait parameters in Parkinson disease (PD) patients using 2D-RGB video-based analysis and explore their relationships with imbalance.

Methods: We prospectively enrolled PD patients for clinical assessments, balance analysis and gait with 180' turning. Spatiotemporal gait parameters during turning were derived based on video-based analysis and correlated with modified Hoehn and Yahr (mHY) stages and center of pressure (COP) oscillations.

View Article and Find Full Text PDF

Background: The efficacy of subthalamic stimulation on axial signs of Parkinson's disease (PD) is debated in the literature. This study delves into the dynamic interplay of gait and posture, specifically probing their nuanced response to subthalamic stimulation and levodopa.

Methods: We used wearable sensor technology to examine alterations in the spatiotemporal parameters of gait and posture in individuals with PD before and 6 months after subthalamic deep brain stimulation (STN-DBS) surgery.

View Article and Find Full Text PDF

This study aims to elucidate the biomechanical characteristics of turning in daily life by analyzing the three-step process of approach, turn, and departure phases. The research involved ten healthy young individuals performing straight walking and 90° turns, categorized into Side-Step (SS) and Cross-Step (CS) turns. Using a 17-camera motion capture system and force plates, the study measured joint angles, moments, and center of mass (COM) variations.

View Article and Find Full Text PDF

Simultaneous Localization and Mapping Methods for Snake-like Robots Based on Gait Adjustment.

Biomimetics (Basel)

November 2024

Jiangsu Key Laboratory of Mine Mechanical and Electrical Equipment, School of Mechatronic Engineering, China University of Mining and Technology, Xuzhou 221116, China.

Snake robots require autonomous localization and mapping capabilities for field applications. However, the characteristics of their motion, such as large turning angles and fast rotation speeds, can lead to issues like drift or even failure in positioning and map building. In response to this situation, this paper starts from the gait motion characteristics of the snake robot itself, proposing an improved gait motion method and a tightly coupled method based on IMU and visual information to solve the problem of poor algorithm convergence caused by head-shaking in snake robot SLAM.

View Article and Find Full Text PDF

An augmented reality dual-task intervention improves postural stability in individuals with Parkinson's disease.

Gait Posture

January 2025

Cleveland Clinic, Lerner Research Institute, Department of Biomedical Engineering, 9500 Euclid Ave, Cleveland, OH 44195, USA; Cleveland Clinic, Neurological Institute, Center for Neurological Restoration, 9500 Euclid Ave, Cleveland, OH 44195, USA. Electronic address:

Background: The Dual-task Augmented Reality Treatment (DART) trial recently established that dual-task training (DTT) delivered by a physical therapist or the augmented reality DART platform was effective in improving spatiotemporal gait parameters under single- and dual-task conditions in individuals with Parkinson's disease (PD). Data regarding postural stability were not reported in the primary outcome manuscript.

Objective: The aim of this secondary analysis was to compare the effects of a Traditional DTT intervention delivered by a physical therapist and DTT delivered by the DART platform on postural stability, functional mobility, and turning in individuals with PD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!