Radiation exposure from computed tomography (CT) has received much attention lately in the medical literature and the media, given the relatively high radiation dose that characterizes a CT examination. Although there are a variety of possible strategies for reducing radiation exposure from CT in an individual patient, optimal CT image acquisition requires that the radiologist understand new scanner technology and how to implement the most effective means of dose reduction while maintaining image quality. The authors describe a practical approach to dose reduction in cardiothoracic radiology, discussing CT radiation dose metrics (eg, CT dose index, dose-length product, effective diameter, and size-specific dose estimate) as well as CT scanner parameters that directly or indirectly influence radiation dose (eg, scan length, x-ray tube output, tube current modulation, pitch, image reconstruction techniques [including iterative reconstruction], and noise reduction). These variables are discussed in terms of their relative importance to image quality and the implications of parametric changes for image quality and diagnostic content, and practical recommendations are made for their immediate implementation in the clinical setting. Taken together, the principles of physics and key parameters involved in reducing radiation dose while maintaining image quality can serve as a "survival guide" for a diagnostic radiology practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/rg.346140084 | DOI Listing |
Circ Cardiovasc Interv
January 2025
Department of Cardiology, Ziekenhuis Oost-Limburg, Genk, Belgium (D.M.F.v.d.B., E.M.P., E.W., D.C., E.M., B.F., M.V., J.D., K.A.).
Background: Geographic stent-ostium mismatch is an important predictor of target lesion failure after percutaneous coronary intervention of an aorto-ostial right coronary artery lesion. Optimal visualization of the aorto-ostial plane is crucial for precise stent implantation at the level of the ostium. This study investigates whether preprocedural 3-dimensional computed tomography (3DCT), with determination of the optimal viewing angle, would allow for more precise stent implantation and reduce procedure time, contrast, and radiation dose.
View Article and Find Full Text PDFCureus
December 2024
Physics and Engineering, London Regional Cancer Program, London, CAN.
Introduction: Radiation may unintentionally injure myocardial tissue, potentially leading to radiation-induced cardiac disease (RICD), with the net benefit of non-small cell lung cancer (NSCLC) radiotherapy (RT) due to the proximity of the lung and heart. RTOG-0617 showed a greater reduction in overall survival (OS) comparing higher doses to standard radiation doses in NSCLC RT. VHeart has been reported as an OS predictor in the first- and fifth-year follow-ups.
View Article and Find Full Text PDFFront Immunol
January 2025
Department of Radiation Oncology, Affiliated Hospital of Jiangnan University, Wuxi, China.
Background: Different doses of radiotherapy (RT) exert diverse effects on tumor immunity, although the precise irradiation method remains unknown. This study sought to elucidate the influence of combining different doses of RT with immune checkpoint inhibitors (ICIs) on the infiltration of CD8T cells within tumors, thereby augmenting the anti-tumor response.
Methods: Constructing a mouse model featuring bilateral lung cancer tumors subjected to high and low dose irradiation, the analysis of RNA transcriptome sequencing data and immunohistochemical validation for tumors exposed to various dosages guided the selection of the optimal low-dose irradiation scheme.
Clin Transl Radiat Oncol
March 2025
Radiation Oncology Department, Cancer Institute Hospital, Japanese Foundation for Cancer Research, 3-8-31 Ariake, Koto-ku, Tokyo 135-8550, Japan.
Background And Purpose: In lung stereotactic body radiation therapy (SBRT) using a breath-holding technique, displacement of tumor during breath-holding is rarely considered. This study used four-dimensional (4D) dose calculation with cine computed tomography (CT) to evaluate the impact of unexpected tumor position displacement during breath-holding on the target dose of lung volumetric modulated arc therapy (VMAT)-SBRT.
Materials And Methods: This study included 20 cases for which tumor position displacement during end-exhalation breath-holding (range: 0.
Clin Transl Radiat Oncol
March 2025
Department of Molecular Genetics, Oncode Institute, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, the Netherlands.
Background And Purpose: Understanding the cellular and molecular effect of proton radiation, particularly the increased DNA damage complexity at the distal end of the Bragg curve, is current topic of investigation. This work aims to study clonogenic survival and DNA damage foci kinetics of a head and neck squamous cell carcinoma cell line at various positions along a double passively scattered Bragg curve. Complementary studies are conducted to gain insights into the link between cell survival variations, experimentally yielded foci and the number and complexity of double strand breaks (DSBs).