Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A number of literature reports showed that argon provides a more sonochemical activity than polyatomic gases because of its higher polytropic ratio; whereas several recent studies showed that polyatomic gases, such as O₂, can compensate the lower bubble temperature by the self decomposition in the bubble. In this work, we show for the first time a numerical interpretation of these controversial reported effects. Computer simulations of chemical reactions inside a collapsing acoustic bubble in water saturated by different gases (Ar, O₂, air and N₂) have been performed for different frequencies (213-1100 kHz). In all cases, OH radical is the main powerful oxidant created in the bubble. Unexpectedly, the order of saturating gases toward the production rate of OH radical was strongly frequency dependent. The rate of production decreases in the order of Ar>O₂>air>N₂ for frequencies above 515 kHz, and Ar starts to lose progressively its first order to the following gases with a gradually decreasing of frequency below 515 kHz up to a final order of O₂>air∼N₂>Ar at 213 kHz. The analysis of chemical kinetic results showed a surprising aspect: in some cases, there exists an optimum bubble temperature during collapse at which the chemical yield is much higher than that of the maximum bubble temperature achieved in the bubble. On the basis of this, we have concluded that the lower sonochemical activity induced by Ar for frequencies below 515 kHz is mainly due to the forte consumption of radicals inside a bubble prior the complete collapse being reached.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ultsonch.2014.09.009 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!