A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and radiographic outcomes of an accelerometer-based system for the tibial resection in total knee arthroplasty. | LitMetric

Purpose: The accelerometer-based system is a portable surgical navigation system for TKA that does not require the use of a large computer console for registration and alignment feedback as required in computer-assisted surgery (CAS). The purpose of this prospective study was to determine the accuracy of the accelerometer-based system in the tibial component positioning and also to evaluate clinical outcomes.

Methods: Between December 2011 and July 2012, a total of 53 consecutive patients with primary gonarthrosis were prospectively enrolled for unilateral TKA using a handheld surgical navigation system to perform the tibial resection. Pre-operatively and postoperatively, patients were asked to fill out a visual analogue scale for pain (VAS) and a knee injury and osteoarthritis outcome score (KOOS). Standing antero-posterior (AP) hip-knee-ankle (HKA) and lateral knee-to-ankle radiographs were performed to determine the varus/valgus alignment and the posterior slope of the tibial components relative to the mechanical axis.

Results: The mean duration of follow-up was 23 months. Average preoperative VAS was 8.3 ± 0.67, which significantly improved to a mean 1.2 ± 0.57 at final follow up (P < 0.001). All scores significantly increased compared with pre-operative scores, except for the KOOS sport component (P = 0.075) and quality of life (P = 0.19). Intra-operatively, the average reading provided by the system with regard to varus/valgus alignment before performing the tibial resection was 0.55° ± 0.43. The average postoperative radiographic alignment of the tibial component in the coronal plane was 0.65° ± 0.59 of deviation by the ideal alignment (P > 0.05).

Conclusion: This study demonstrates that the OrthAlign navigation system combines the accuracy of the computer-assisted surgery systems with the ease of use and familiarity of the traditional instruments while avoiding the drawbacks of the CAS technique and disadvantages of conventional IM femoral alignment systems. The system could demonstrate an improvement in the incidence of outliers in final coronal alignment, as compared with a patient-specific cutting guide.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00264-014-2541-5DOI Listing

Publication Analysis

Top Keywords

accelerometer-based system
12
navigation system
12
system tibial
8
tibial resection
8
surgical navigation
8
computer-assisted surgery
8
system
7
clinical radiographic
4
radiographic outcomes
4
outcomes accelerometer-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!