A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical impact of 3-dimensional balanced turbo-field-echo magnetic resonance cholangiopancreatography at 3 T: prospective intraindividual comparison with 3-dimensional turbo-spin-echo magnetic resonance cholangiopancreatography. | LitMetric

Objective: The objective of this study was to evaluate the clinical utility of 3-dimensional (3D) balanced turbo-field-echo (BTFE) magnetic resonance cholangiopancreatography (MRCP) with gate and track acquisition at 3 T.

Methods: Using a 3-T unit, we subjected 52 consecutive patients to 3D BTFE MRCP with the navigator-gated technique and 3D turbo-spin-echo volume isotropic T2-weighted acquisition (VISTA) MRCP with the navigator-triggered technique. Two radiologists independently rated the image quality and visibility of the right and left hepatic duct, cystic duct, common bile duct, gallbladder, and main pancreatic duct using a 4-point scale. The signal-to-noise ratio, contrast-to-noise ratio, and the acquisition time were evaluated by quantitative analysis.

Results: The visual scores of the cystic duct, common bile duct, gallbladder, and overall image quality were significantly higher for BTFE than VISTA MRCP (P < 0.01). The score for the main pancreatic duct was significantly higher with VISTA MRCP (P < 0.01). The image acquisition time was significantly shorter with BTFE than VISTA MRCP (139.8 ± 45.4 vs 416.9 ± 108.3 seconds, P < 0.01). There was no significant difference in signal-to-noise ratio and contrast-to-noise ratio.

Conclusions: Three-dimensional BTFE MRCP yields significantly better image quality and visibility of large biliary structures than VISTA MRCP at a significantly shorter acquisition time. Volume isotropic T2-weighted acquisition MRCP provides detailed information on the main pancreatic duct that tends to be obscure on the 3D BTFE sequence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/RCT.0000000000000163DOI Listing

Publication Analysis

Top Keywords

vista mrcp
20
magnetic resonance
12
resonance cholangiopancreatography
12
image quality
12
main pancreatic
12
pancreatic duct
12
acquisition time
12
mrcp
9
3-dimensional balanced
8
balanced turbo-field-echo
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!