We report on tests of the shifted potential (SP), gradient shifted force (GSF), and Taylor shifted force (TSF) real-space methods for multipole interactions developed in Paper I of this series, using the multipolar Ewald sum as a reference method. The tests were carried out in a variety of condensed-phase environments designed to test up to quadrupole-quadrupole interactions. Comparisons of the energy differences between configurations, molecular forces, and torques were used to analyze how well the real-space models perform relative to the more computationally expensive Ewald treatment. We have also investigated the energy conservation, structural, and dynamical properties of the new methods in molecular dynamics simulations. The SP method shows excellent agreement with configurational energy differences, forces, and torques, and would be suitable for use in Monte Carlo calculations. Of the two new shifted-force methods, the GSF approach shows the best agreement with Ewald-derived energies, forces, and torques and also exhibits energy conservation properties that make it an excellent choice for efficient computation of electrostatic interactions in molecular dynamics simulations. Both SP and GSF are able to reproduce structural and dynamical properties in the liquid models with excellent fidelity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1063/1.4896628 | DOI Listing |
J Biomech Eng
January 2025
Department of orthopedics, the Second Affiliated Hospital of Medical College of Zhejiang University, Hangzhou, Zhejiang, 310000, China.
This study aims to compare the sinking and shifting of an enhanced escape-proof intervertebral fusion device with a traditional TLIF intervertebral fusion device.Five specimens each of the improved escape-resistant intervertebral cage and the traditional TLIF cage were selected. Four types of mechanical tests were conducted on each cage, Furthermore, a blade-cutting torque test was performed on the escape-resistant cage, with the recording of load-displacement curves and mechanical values.
View Article and Find Full Text PDFBMC Geriatr
January 2025
James P. Wilmot Cancer Institute, Rochester, New York, USA.
Background: Older adults with cancer are vulnerable to declines in muscle performance (e.g., strength, speed, duration of muscular contraction), which are associated with worse cancer-related outcomes.
View Article and Find Full Text PDFJ Geriatr Phys Ther
November 2024
Department of Physical Therapy and Rehabilitation Science, University of Maryland School of Medicine, Baltimore, Maryland.
Background And Purpose: Muscle strength, power, and mass decline with aging, leading to functional loss highly correlated with balance and falls in older adults. Lower limb muscle function is critical for fall prevention in older adults, and hip abductor force and rapid force development have been shown to be important during stepping tasks. However, it remains unclear whether hip abductor muscle function changes with aging.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Department of Physics, Chalmers University of Technology, 412 96, Gothenburg, Sweden.
Nanostructured dielectric metasurfaces offer unprecedented opportunities to control light-matter momentum exchange, and thereby the forces and torques that light can exert on matter. Here we introduce optical metasurfaces as components of ultracompact untethered microscopic metaspinners capable of efficient light-induced rotation in a liquid environment. Illuminated by weakly focused light, a metaspinner generates torque via photon recoil through the metasurfaces' ability to bend light towards high angles despite their sub-wavelength thickness, thereby creating orbital angular momentum.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Faculty of Mechanical Engineering, Lublin University of Technology, 36 Nadbystrzycka St., 20-618 Lublin, Poland.
This article presents a laboratory device by which the course of two signals can be detected using two types of sensors-strain gauges and the DEWESoft DS-NET measuring apparatus. The values of the coefficient of friction of the brake lining when moving against the rotating shell of the brake drum were determined from the physical quantities sensed by tensometric sensors and transformed into electrical quantities. The friction coefficient of the brake lining on the circumference of the rotating brake disc shell can be calculated from the known values measured by the sensors, the design dimensions of the brake, and the revolutions of the rotating parts system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!