Objective: To determine the relative bioavailability of ethinyl estradiol (EE) and gestodene (GSD) after application of a novel transdermal contraceptive patch vs. a standard combined oral contraceptive (COC) pill (study 1), and to evaluate the pharmacokinetics (PK) of EE after application of the EE/GSD patch compared with an EE/norelgestromin (NGMN) patch (study 2).
Materials: Participants were healthy, nonobese women aged 18 - 45 years (study 1) or 18 - 35 years (study 2). Compositions of study treatments were as follows: 0.55 mg EE/2.1 mg GSD (EE/GSD patch); 0.02 mg EE/0.075 mg GSD (standard COC); 0.6 mg EE/6 mg NGMN (EE/NGMN patch).
Methods: In study 1, which consisted of 3 treatment periods (each followed by 7 patch- or pill-free days), treatments were administered in one of two randomized orders: either P-M-E (EE/GSD patch (P) every 7 days for 28 days → COC (M) once-daily for 21 days → two 7-day patch-wearing periods followed by one 10-day patch-wearing phase (E)), or the same treatments administered in sequence M-P-E. For study 2, participants received either the EE/GSD patch or EE/NGMN patch for seven treatment cycles (one patch per week for 3 weeks followed by a 7-day patch-free interval).
Results: In study 1, average daily exposure to EE was similar for treatments P and M; the mean daily area under the concentration-time curve (AUC) ratio of treatment P vs. treatment M for EE was 1.06 (90% confidence interval (CI): 0.964 - 1.16), indicating average daily delivery similar to oral administration of 0.019 - 0.023 mg EE. For unbound GSD, average daily exposure was lower for treatment P vs. treatment M. The mean AUC ratio of treatment P vs. treatment M for unbound GSD was 0.820 (90% CI: 0.760 - 0.885), indicating average daily delivery from the patch of 0.057 - 0.066 mg GSD. Prolonged patch wearing did not result in a distinct decline in GSD and EE serum concentrations. In study 2, AUC at steady state (AUC0-168,ss), average steady-state serum concentration, and maximum steady-state serum concentration for EE was 2.0 - 2.7-fold higher for the EE/NGMN patch vs. the EE/GSD patch. The EE/GSD patch was well tolerated in both studies.
Conclusions: Based on the 90% CI of the AUC ratio of oral treatment vs. patch application for unbound GSD and EE, the daily doses of GSD and EE released from the EE/GSD patch over the 7-day application period provided the same systemic exposure as those recorded after daily oral administration of a COC containing 0.02 mg EE and 0.06 mg GSD. The EE/GSD patch showed reduced EE exposure compared with the EE/NGMN patch. Together with its good tolerability, these properties support the EE/GSD patch as an effective and well-tolerated alternative to available transdermal and oral contraceptives.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4285808 | PMC |
http://dx.doi.org/10.5414/CP202064 | DOI Listing |
J Obstet Gynaecol
January 2017
a Bayer Pharma AG , Berlin , Germany.
Here we report the findings of a two-centre, open-label, randomised, Phase IIa study designed to investigate whether an ethinyl estradiol (EE)/gestodene (GSD) patch that has been developed (referred to herein as the 'EE/GSD patch') reliably inhibits ovulation in comparison with patches delivering lower doses of these hormones. The study rationale was to provide justification of the doses of EE and GSD selected for the EE/GSD patch. Healthy women, aged 18-35 years, were randomised to receive treatment with either the EE/GSD patch, a 'reduced-GSD patch' (delivering similar amounts of EE and approximately half the amount of GSD) or a 'reduced-EE/GSD patch' (delivering half the amount of EE and GSD).
View Article and Find Full Text PDFContraception
February 2015
Bayer Pharma AG, 13353 Berlin, Germany.
Objective(s): The aim of this study was to investigate the bleeding pattern and cycle control of a contraceptive patch containing 0.55 mg ethinyl estradiol (EE) and 2.1 mg gestodene (GSD) compared with a combined oral contraceptive (COC) containing 0.
View Article and Find Full Text PDFContraception
February 2015
Bayer Pharma AG, 13353 Berlin, Germany. Electronic address:
Objective(s): To investigate the bleeding pattern and cycle control parameters of a contraceptive patch containing 0.55 mg ethinyl estradiol (EE) and 2.1 mg gestodene (GSD) compared with a patch containing 0.
View Article and Find Full Text PDFObjective: To determine the relative bioavailability of ethinyl estradiol (EE) and gestodene (GSD) after application of a novel transdermal contraceptive patch vs. a standard combined oral contraceptive (COC) pill (study 1), and to evaluate the pharmacokinetics (PK) of EE after application of the EE/GSD patch compared with an EE/norelgestromin (NGMN) patch (study 2).
Materials: Participants were healthy, nonobese women aged 18 - 45 years (study 1) or 18 - 35 years (study 2).
Objectives: A novel once-a-week contraceptive patch delivers the same systemic exposure seen with a combined oral contraceptive pill containing 0.02 mg ethinyl estradiol (EE) and 0.06 mg gestodene (GSD).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!