A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The accuracy of C-reactive protein, procalcitonin, and s-TREM-1 in the prediction of serious bacterial infection in neonates. | LitMetric

Unlabelled: In this prospective study, we examined the usefulness of C-reactive protein (CRP), soluble triggering receptor expressed on myeloid cells (s-TREM-1), and procalcitonin (PCT), in identifying serious bacterial infection (SBI) among neonates. Infants younger than 3 months with suspected SBI were included and serum concentrations of CRP, PCT, and s-TREM-1 were determined.

Results: A total of 112 patients (19 with SBI and 93 with negative cultures) were evaluated. There were no statistical differences between the 2 groups regarding age, presence of fever, and serum concentrations of the different biomarkers. Performance of the different biomarkers were as follows: The sensitivities were 45%, 55%, and 82% for CRP, PCT, and s-TREM-1, respectively, whereas the specificities we 82%, 75%, and 48% for CRP, PCT, and s-TREM-1, respectively. The areas under the receiver operating characteristic curve were 0.6, 0.63, and 0.61, for CRP, PCT, and s-TREM-1, respectively.

Conclusions: In real-life pediatric practice, none of the tested biomarkers was sufficiently accurate to serve as a reliable indicator for the identification of SBI in neonates.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0009922814553435DOI Listing

Publication Analysis

Top Keywords

crp pct
16
pct s-trem-1
16
c-reactive protein
8
serious bacterial
8
bacterial infection
8
sbi neonates
8
serum concentrations
8
s-trem-1
6
crp
5
pct
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!