Introduction: The airborne transmission of infectious diseases in livestock production is increasingly receiving research attention. Reliable techniques of air sampling are crucial to underpin the findings of such studies. This study evaluated the physical and biological efficiencies and detection limits of four samplers (Andersen 6-stage impactor, all-glass impinger "AGI-30", OMNI-3000 and MD8 with gelatin filter) for collecting aerosols of infectious bursal disease virus (IBDV).

Materials And Method: IBDV aerosols mixed with a physical tracer (uranine) were generated in an isolator, and then collected by the bioaerosol samplers. Samplers' physical and biological efficiencies were derived based on the tracer concentration and the virus/tracer ratio, respectively. Detection limits for the samplers were estimated with the obtained efficiency data.

Results: Physical efficiencies of the AGI-30 (96%) and the MD8 (100%) were significantly higher than that of the OMNI-3000 (60%). Biological efficiency of the OMNI-3000 (23%) was significantly lower than 100% (P < 0.01), indicating inactivation of airborne virus during sampling. The AGI-30, the Andersen impactor and the MD8 did not significantly inactivate virus during sampling. The 2-min detection limits of the samplers on airborne IBDV were 4.1 log10 50% egg infective dose (EID50) m (-3) for the Andersen impactor, 3.3 log10 EID50 m (-3) for the AGI-30, 2.5 log10 EID50 m (-3) for the OMNI-3000, and 2.9 log10 EID50 m (-3) for the MD8. The mean half-life of IBDV aerosolized at 20 °C and 70% was 11.9 min.

Conclusion: Efficiencies of different samplers vary. Despite its relatively low sampling efficiency, the OMNI-3000 is suitable for use in environments with low viral concentrations because its high flow rate gives a low detection limit. With the 4 samplers investigated, negative air samples cannot guarantee virus-free aerial environments, which means that transmission of infectious agents between farms may still occur even when no virus has been detected.

Download full-text PDF

Source
http://dx.doi.org/10.5604/12321966.1120585DOI Listing

Publication Analysis

Top Keywords

detection limits
16
virus sampling
12
limits samplers
12
log10 eid50
12
airborne virus
8
efficiencies samplers
8
infectious bursal
8
bursal disease
8
disease virus
8
transmission infectious
8

Similar Publications

Assessing the Efficacy of Pyrolysis-Gas Chromatography-Mass Spectrometry for Nanoplastic and Microplastic Analysis in Human Blood.

Environ Sci Technol

January 2025

Queensland Alliance for Environmental Health Sciences (QAEHS), The University of Queensland, 20 Cornwall Street, Woolloongabba, Queensland 4102, Australia.

Humans are constantly exposed to micro- and nanosized plastics (MNPs); however, there is still limited understanding of their fate within the body, partially due to limitations with current analytical techniques. The current study assessed the appropriateness of pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) analysis for the quantification of a range of polymers in human blood. An extraction protocol that reduced matrix interferences (false positives) of polyethylene (PE) and polyvinyl chloride (PVC) was developed and validated.

View Article and Find Full Text PDF

The efficient immobilization of capture antibodies is crucial for timely pathogen detection during global pandemic outbreaks. Therefore, we proposed a silica-binding protein featuring core functional domains (cSP). It comprises a peptide with a silica-binding tag designed to adhere to silica surfaces and tandem protein G fragments (2C2) for effective antibody capture.

View Article and Find Full Text PDF

The overuse of antibiotics has led to the severe contamination of water bodies, posing a considerable hazard to human health. Therefore, the development of an accurate and rapid point-of-care testing (POCT) platform for the quantitative detection of antibiotics is necessary. In this study, Cerium oxide (CeO) and Ferrosoferric oxide (FeO) nanoparticles were simultaneously encapsulated into N-doped nanofibrous carbon microspheres to form of a novel nanozyme (CeFe-NCMzyme) with a porous structure, high surface area, and N-doped carbon material properties, leading to a considerable enhancement of the peroxidase (POD)-like activity compared with that of the CeO or FeO nanoparticles alone.

View Article and Find Full Text PDF

Heparin (HEP) is one of the oldest anticoagulant drugs, widely used in clinical settings, particularly in surgery and dialysis machines. Despite its long history, it remains extensively employed in medical practice. This study introduces a selective and cost-effective method for the rapid detection of HEP using red-emission carbon dots (R-CDs).

View Article and Find Full Text PDF

An on-site, sensitive, and cost-effective method for determining aflatoxin B1 (AFB1) in rice samples is proposed, combining magnetic solid phase extraction (MSPE) and time-resolved fluorescence immunochromatography (TRFICA) techniques. Cost-effective rice husks were carbonized and combined with nanomaterials to make magnetic nanocomposites that acted as effective adsorbents in MSPE. Under optimal conditions, the entire process was completed in 15 min with a visual detection limit of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!