Objective: To describe the use of a wire snare technique for epiglottic entrapment.
Study Design: Case series.
Animals: Eight adult horses.
Methods: Under general anesthesia, a modified mouth gag was placed in the oropharynx. An endoscope was passed through the gag until there was adequate visualization of the entrapped epiglottis. The entrapping mucosa was grasped with bronchoesophageal forceps and pulled rostrally, releasing the epiglottis. A custom snare was passed down the bronchoesophageal forceps to encircle the redundant subepiglottic mucosa. Tension was applied to the entrapping mucosa via the forceps as the obstetric wire was tightened at the base and the redundant mucosa (aryepiglottic fold) was excised.
Results: The procedure was performed on 8 adult thoroughbred horses. Re-evaluation by endoscopy did not show entrapment in any horse and no horse developed complications or has had problems with performance.
Conclusions: This technique is a minimally invasive, competitively priced and straightforward method for resection of entrapping subepiglottic mucosa in adult horses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1532-950X.2014.12280.x | DOI Listing |
ACG Case Rep J
January 2025
Department of Gastroenterology and GI Endoscopy, University Hospital, Ferrara, Italy.
J Cardiovasc Electrophysiol
January 2025
Department of Cardiovascular Medicine, Toho University Graduate School of Medicine, Tokyo, Japan.
Introduction: The docking button of the Aveir leadless pacemaker (LP) is occasionally difficult to access due to its inappropriate position in the right ventricle (RV).
Methods And Results: We report a case where the Aveir LP was successfully retrieved by releasing the wedged docking button in the inferior wall of the RV using a loop wire technique.
Conclusion: The loop wire technique may be useful to change the position of the Aveir LP.
Sci Rep
December 2024
Department of Molecular Gastroenterology and Hepatology, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto, 602-8566, Japan.
Accidental bending of the snare sheath occasionally occurs during cold snare polypectomy (CSP). We aimed to demonstrate whether snare bending reduces resection ability and, if it does, what causes this reduction. Using currently available CSP snares and prototype snares, we investigated changes in the resection ability of bent snares as well as the stiffness of their sheaths and wire spindles.
View Article and Find Full Text PDFEndoscopy
December 2024
Gastroenterology, People's Hospital of Leshan, Leshan, China.
Catheter Cardiovasc Interv
January 2025
Interventional Center of Valvular Heart Disease, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Transcatheter aortic valve replacement (TAVR) procedure was planned for a 68-year-old female patient diagnosed with severe aortic stenosis by transthoracic echocardiography. The first valve unexpectedly dislodged during catheter tip withdrawal after full deployment. A second valve deployment became necessary, posing challenges due to the difficulty of passing the second valve delivery system through the first valve frame.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!