A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Suppression of the sidewall effect in pillar array columns with radially elongated pillars. | LitMetric

Suppression of the sidewall effect in pillar array columns with radially elongated pillars.

J Chromatogr A

Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium. Electronic address:

Published: November 2014

An important bottleneck of pillar array columns designed for liquid chromatography is that small deviations of the target 'magical distance' at the sidewall region leads to detrimental sidewall effects, due to local differences of linear velocities at the sidewall region versus other locations in the pillar bed. In the present study, we demonstrate that a lateral elongation of the pillar significantly increases the tolerance for offsets of the magical distance. By shifting the sidewall distance 600 nm for 2 pillar aspect ratio (AR) designs (AR=3 and 9), only minor sidewall effects on the measured plate heights could be observed for the AR=9 columns, while the plate height was roughly doubled when using the wrong versus the correct sidewall distance for the AR=3 columns. Technologically, this constitutes a huge advantage because small deviations (order of 100 nm) between the set and the finally achieved value for the inter-pillar distance are very common using mid-UV lithography based etching processes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2014.09.052DOI Listing

Publication Analysis

Top Keywords

pillar array
8
array columns
8
small deviations
8
sidewall region
8
sidewall effects
8
sidewall distance
8
sidewall
6
pillar
5
suppression sidewall
4
sidewall pillar
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!