Background: Independent-components-analysis (ICA) successfully separated electrically-evoked compound action potentials (ECAPs) from the stimulation artefact and noise (ECAP-ICA, Akhoun et al., 2013).
New Method: This paper shows how to automate the ECAP-ICA artefact cancellation process. Raw-ECAPs without artefact rejection were consecutively recorded for each stimulation condition from at least 8 intra-cochlear electrodes. Firstly, amplifier-saturated recordings were discarded, and the data from different stimulus conditions (different current-levels) were concatenated temporally. The key aspect of the automation procedure was the sequential deductive source categorisation after ICA was applied with a restriction to 4 sources. The stereotypical aspect of the 4 sources enables their automatic classification as two artefact components, a noise and the sought ECAP based on theoretical and empirical considerations.
Results: The automatic procedure was tested using 8 cochlear implant (CI) users and one to four stimulus electrodes. The artefact and noise sources were successively identified and discarded, leaving the ECAP as the remaining source. The automated ECAP-ICA procedure successfully extracted the correct ECAPs compared to standard clinical forward masking paradigm in 22 out of 26 cases.
Comparison With Existing Method(s): ECAP-ICA does not require extracting the ECAP from a combination of distinct buffers as it is the case with regular methods. It is an alternative that does not have the possible bias of traditional artefact rejections such as alternate-polarity or forward-masking paradigms.
Conclusions: The ECAP-ICA procedure bears clinical relevance, for example as the artefact rejection sub-module of automated ECAP-threshold detection techniques, which are common features of CI clinical fitting software.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jneumeth.2014.09.027 | DOI Listing |
J Neurosci Methods
December 2024
Ecole Nationale de l'Aviation Civile, (ENAC), Toulouse 31300, France. Electronic address:
Background: Fast-ripples (FR) are short (∼10 ms) high-frequency oscillations (HFO) between 200 and 600 Hz that are helpful in epilepsy to identify the epileptogenic zone. Our aim is to propose a new method to detect FR that had to be efficient for intracerebral EEG (iEEG) recorded from both usual clinical macro-contacts (millimeter scale) and microwires (micrometer scale).
New Method: Step 1 of the detection method is based on a convolutional neural network (CNN) trained using a large database of > 11,000 FR recorded from the iEEG of 38 patients with epilepsy from both macro-contacts and microwires.
Diagnostics (Basel)
November 2024
Department of Electrical and Computer Engineering, Faculty of Engineering, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
Naturally, there are several challenges, such as muscular artifacts, ocular movements and electrical interferences that depend on precise diagnosis and classification, which hamper exact epileptic seizure detection. This study has been conducted to improve seizure detection accuracy in epilepsy patients using an advanced preprocessing technique that could remove such noxious artifacts. In the frame of this paper, the core tool in the area of epilepsy, EEG, will be applied to record and analyze the electrical patterns of the brain.
View Article and Find Full Text PDFCommun Med (Lond)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, 55905, USA.
Background: While high-frequency oscillations (HFOs) and their stereotyped clusters (sHFOs) have emerged as potential neuro-biomarkers for the rapid localization of the seizure onset zone (SOZ) in epilepsy, their clinical application is hindered by the challenge of automated elimination of pseudo-HFOs originating from artifacts in heavily corrupted intraoperative neural recordings. This limitation has led to a reliance on semi-automated detectors, coupled with manual visual artifact rejection, impeding the translation of findings into clinical practice.
Methods: In response, we have developed a computational framework that integrates sparse signal processing and ensemble learning to automatically detect genuine HFOs of intracranial EEG data.
Clin Nucl Med
December 2024
From the Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland.
Introduction: We propose a fully automated framework to conduct a region-wise image quality assessment (IQA) on whole-body 18 F-FDG PET scans. This framework (1) can be valuable in daily clinical image acquisition procedures to instantly recognize low-quality scans for potential rescanning and/or image reconstruction, and (2) can make a significant impact in dataset collection for the development of artificial intelligence-driven 18 F-FDG PET analysis models by rejecting low-quality images and those presenting with artifacts, toward building clean datasets.
Patients And Methods: Two experienced nuclear medicine physicians separately evaluated the quality of 174 18 F-FDG PET images from 87 patients, for each body region, based on a 5-point Likert scale.
Biomed Phys Eng Express
October 2024
R&D, Neurocare Group AG, Munich, Germany.
Automation is revamping our preprocessing pipelines, and accelerating the delivery of personalized digital medicine. It improves efficiency, reduces costs, and allows clinicians to treat patients without significant delays. However, the influx of multimodal data highlights the need to protect sensitive information, such as clinical data, and safeguard data fidelity.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!