A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of intra-aneurysmal flow modification after flow diverter stent placement with four-dimensional flow MRI: a feasibility study. | LitMetric

Background: Flow diverter stents (FDS) have been effectively used for the endovascular treatment of sidewall intracranial aneurysms (IAs). Unlike standard endovascular treatments used to exclude directly the aneurysm bulge from the parent vessel, FDS induce reduction in the intra-aneurysmal flow and promote progressive and stable thrombosis therein. The advent of FDS has therefore increased the need for understanding of IA hemodynamics.

Methods: We proposed the use of the most recently evolved four-dimensional (4D) flow MRI technique to evaluate qualitatively and quantitatively post-FDS flow modification in 10 patients. We report intra-aneurysmal velocity measurements and the influence of metal artifacts induced by the stent.

Results: An index was defined to quantitatively measure flow changes-namely, the proportional velocity reduction ratio (PVRR)-with ranges from 34.6% to 71.1%. Furthermore, we could compare streamlines characterizing the post-stent flow patterns in five patients in whom the intra-aneurysmal velocity was beyond the visualization threshold of 7.69 cm/s.

Conclusions: Despite metal artifacts and the low velocities involved, 4D flow MRI could be of interest to measure qualitatively and quantitatively flow changes in stented aneurysms. However, further enhancements are required together with further validation work before it can be considered for clinical use.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2014-011348DOI Listing

Publication Analysis

Top Keywords

flow mri
12
flow
11
intra-aneurysmal flow
8
flow modification
8
flow diverter
8
four-dimensional flow
8
qualitatively quantitatively
8
intra-aneurysmal velocity
8
metal artifacts
8
assessment intra-aneurysmal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!