Context: Urine specific gravity (Usg), measured by a handheld manual refractometer (MAN), has been recognized as a valid and practical means of assessing hydration status. Newer, digital refractometers are faster and more user friendly but have not been validated against the traditional MAN.
Objective: To compare the reliability and validity of 2 digital refractometer models and a MAN.
Design: Descriptive laboratory study.
Setting: Research laboratory.
Patients Or Other Participants: Sample of convenience was recruited from the local university and surrounding community (n = 82).
Intervention(s): Participants provided multiple urine samples (n = 124) over a 5-month period under various hydration conditions.
Main Outcome Measure(s): Urine specific gravity was compared among a MAN, a digital refractometer requiring the prism to be dipped (DIP) into a urine sample, and a digital refractometer that requires urine to be pipetted (PIP) onto its prism for analysis.
Results: The MAN measurements were strongly correlated with the DIP (r = 0.99, P < .001) and PIP (r = 0.97, P < .001) measurements. Bland-Altman analyses revealed slight mean underestimation (95% upper and lower levels of agreement) between MAN and DIP (-0.0012 [0.0028] and PIP -0.0011 [0.0035], respectively) and trends toward increased underestimation at higher Usg. Measurement error ≥ .005 was greater for PIP (4/124, 3.2%) than for DIP (2/124, 1.6%).
Conclusions: Negligible differences were exhibited between PIP and DIP, with both displaying acceptable reliability and validity compared with the MAN. However, the Bland-Altman analysis suggests underestimation bias for the DIP and PIP as Usg increases, with the potential for rare but substantial underestimation when using PIP that should be recognized by clinicians, particularly when used as a screening measure in weight-class sports.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4299737 | PMC |
http://dx.doi.org/10.4085/1062-6050-49.3.47 | DOI Listing |
Shock
January 2025
Department of Anesthesiology, The University of Texas Medical Branch, Galveston, Texas.
Introduction: The understanding of the interaction of closed-loop control of ventilation and oxygenation, specifically fraction of inspired oxygen (FiO2) and positive end-expiratory pressure (PEEP), and fluid resuscitation after burn injury and acute lung injury from smoke inhalation is limited. We compared the effectiveness of FiO2, PEEP, and ventilation adjusted automatically using adaptive support ventilation (ASV) and decision support fluid resuscitation based on urine output in a clinically relevant conscious ovine model of lung injury secondary to combined smoke inhalation and major burn injury.
Methods: Sheep were subjected to burn and smoke inhalation injury under deep anesthesia and analgesia.
Pract Lab Med
January 2025
Department of Pharmaceutical Sciences, School of Pharmaceutical Science, Babasaheb Bhimrao Ambedkar University, Vidya Vihar, Raebareli Road, 226025, Lucknow, India.
Liquid biopsy is an innovative, minimally invasive diagnostic tool revolutionizing cancer management by enabling the detection and analysis of cancer-related biomarkers from bodily fluids such as blood, urine, or cerebrospinal fluid. Unlike traditional tissue biopsies, which require invasive procedures, liquid biopsy offers a more accessible and repeatable method for tracking cancer progression, detecting early-stage cancers, and monitoring therapeutic responses. The technology primarily focuses on analyzing circulating tumor cells (CTCs), circulating tumor DNA (ctDNA), and other cancer-derived genetic materials.
View Article and Find Full Text PDFFront Med (Lausanne)
January 2025
Department of Central Laboratory, Shenzhen Hospital, Beijing University of Chinese Medicine, Shenzhen, Guangdong, China.
Objective: The effectiveness of using as an adjuvant therapy for patients with renal dysfunction (RD), especially acute kidney injury (AKI), is still a topic of debate. In response to the current conflicting data, the present meta-analysis was conducted to assess the clinical effectiveness of in the treatment of RD and to provide evidence for clinical practice.
Methods: Several databases, including PubMed, EMBASE, Cochrane Library, China National Knowledge Infrastructure (CNKI) and Wanfang, were systematically searched updated to March 25, 2024.
Front Public Health
January 2025
Department of Animal Sciences, Global Food Systems Institute, and Emerging Pathogens Institute, University of Florida, Gainesville, FL, United States.
Background: is associated with environmental enteric dysfunction (EED) and malnutrition in children. infection could be a linchpin between livestock fecal exposure and health outcomes in low-resource smallholder settings.
Methods: We followed a birth cohort of 106 infants in rural smallholder households in eastern Ethiopia up to 13 months of age.
Parasitology
January 2025
Tropical Medicine Unit, Hospital Universitario Poniente, Ctra. de Almerimar 31, 04700 El Ejido, Spain.
Different agencies have emphasized the need to evaluate current serological methods for screening patients with suspected urogenital schistosomiasis. However, there is still a lack of evidence regarding the most appropriate methods for this purpose. Here we assessed the diagnostic efficacy of a newly developed serological technique that utilizes the recombinant protein -TSP-2, applied to the urine and serum of migrants suspected of having urogenital schistosomiasis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!