A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of Becton Dickinson Plain and Serum Separator Tubes in Measurement of 25-Hydroxyvitamin D3 (25OHD3) by HPLC and Immunoassay Methods. | LitMetric

Background: The accuracy of 25-hydroxyvitamin D3 (25OHD3) measurement on specimens collected into serum separator tubes (SSTs) has been questioned because of possible interference by the gel. Possible interference was investigated in SSTs from Becton Dickinson (BD).

Design And Methods: Blood specimens were collected simultaneously from 50 normal subjects into plain tubes and SSTs. 25OHD3 was assayed on serum using high performance liquid chromatography (Chromsystems), and Architect (Abbott) and Liaison (Diasorin) immunoassays.

Results: There were no significant differences between 25OHD3 results (means ± SE, nmol/l) obtained from specimens collected into plain tubes and SSTs assayed by HPLC (39.0 ± 2.7 vs. 39.3 ± 2.7), Liaison (32.9 ± 2.2 vs. 32.8 ± 2.3), or Architect (43.1 ± 2.8 vs. 43.2 ± 2.8). In specimens collected into plain tubes and SSTs, 25OHD3 measurements by HPLC correlated significantly (P < 0.0001) with those from the Architect (r = 0.895, r = 0.908) and Liaison (r = 0.907, r = 0.913), respectively.

Conclusions: The gel in SSTs (BD) does not interfere with the measurement of 25OHD3 by HPLC or common immunoassays. This important finding may enable clinical laboratories to make cost savings by using SSTs without concerns about inaccuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6807202PMC
http://dx.doi.org/10.1002/jcla.21805DOI Listing

Publication Analysis

Top Keywords

specimens collected
16
tubes ssts
16
plain tubes
12
becton dickinson
8
serum separator
8
separator tubes
8
25-hydroxyvitamin 25ohd3
8
25ohd3 hplc
8
ssts 25ohd3
8
collected plain
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!