The effects of anterior vacuum disc on surgical outcomes of degenerative versus spondylolytic spondylolisthesis: at a minimum two-year follow-up.

BMC Musculoskelet Disord

Department of Orthopedic Surgery, Chang Gung Memorial Hospital, Chang Gung University, No,_5, Fu-Shin Street, Kweishian, Taoyuan 333, Taiwan.

Published: October 2014

Background: The vacuum phenomenon within the intervertebral disc usually represents disc degeneration. There are no reports in the English literature that focus on the effect of an anterior vacuum disc on surgical outcome of same-segment spondylolisthesis.

Methods: Patients with degenerative spondylolisthesis (DS) or isthmic spondylolisthesis (IS) who underwent a spinal surgery between January 2005 and December 2006 were reviewed. Patients who met certain criteria, including (1) only mono-segment spondylolisthesis, (2) gas air within the disc space of the spondylolisthesis segment on preoperative radiographs, (3) having received posterior decompression, posterior pedicle screw fixation, and posterolateral fusion, and (4) at least 12 months of follow-up radiographs available to define the posterolateral fusion rate, were enrolled into the study. Four radiographic parameters (disc height, translation, intradiscal angle, segmental angle) were assessed. Two-year postoperative radiographs were used to determine whether the posterolateral segment was fused or not. Clinical outcome and complications during the follow-up period were documented.

Results: Incidence of the disc vacuum phenomenon was significantly higher in the IS group than in the DS group (p < 0.001). The IS group had more listhesis and a narrower disc height on preoperative static radiographs; however, the DS group had a more prominent angle and listhesis change in preoperative dynamic variables. The posterolateral fusion rate was significantly higher in the IS group (p = 0.019). The preoperative Oswestry Disability Index (ODI) score, the final ODI, and the ODI difference were similar between groups. More excellent and good results were seen in the IS group. Besides, better final ODI and results were seen in the bilateral fusion group than in the nonfusion group.

Conclusion: The disc vacuum phenomenon is not equal to anterior instability absolutely. Determination of stability or instability in a vacuum disc should be considered by a combination of dynamic radiographs. In the present study, vacuum discs in the DS group showed more instability and a higher posterolateral pseudoarthrosis rate.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4201703PMC
http://dx.doi.org/10.1186/1471-2474-15-329DOI Listing

Publication Analysis

Top Keywords

anterior vacuum
8
vacuum disc
8
disc surgical
8
vacuum phenomenon
8
posterolateral fusion
8
disc
7
spondylolisthesis
5
effects anterior
4
vacuum
4
surgical outcomes
4

Similar Publications

Purpose: The aim of this study was to use calorimetry to understand the difference in energy transferred by three phacoemulsification surgical platforms to the eye.

Patients And Methods: A phacoemulsification tip was lowered into a double-walled calorimeter filled with distilled water. The foot pedal was depressed for 30 seconds and the change in temperature of the water was measured by a temperature probe.

View Article and Find Full Text PDF

Aim: To measure the optimal anterior chamber pressure (ACP) for safe phacoemulsification using a new tube chamber system with internal pressure measurement function in the porcine eye.

Methods: The 20-gauge and 21-gauge straight tips with yellow and orange sleeves, respectively, were covered by a test chamber combined with a pressure sensor for measuring ACP. This was measured for 20s from 10s after starting aspiration in the linear mode using vacuum levels of 200 and 150 mm Hg with a 20-gauge tip, and 300 and 250 mm Hg with a 21-gauge tip.

View Article and Find Full Text PDF

Pectus excavatum, also known as sunken chest or funnel chest, is a structural deformity of the anterior chest wall, characterized by an inward sternum. This condition can lead to respiratory and cardiovascular issues, although it is often addressed for aesthetic reasons. This perspective article reviews the experiences of multiple centers in treating pectus excavatum, to explore whether a clear boundary exists between pathological and aesthetic needs.

View Article and Find Full Text PDF

Perineal deformation during forceps, vacuum and OdonAssist™ assisted vaginal deliveries: A simulation study based on advanced image processing.

Eur J Obstet Gynecol Reprod Biol

January 2025

Department of Obstetrics and Gynecology, Jean Minjoz Hospital, Besançon University Medical Center - Alexander Fleming Boulevard, 25000 Besançon, France; University of Franche-Comte-SINERGIE Laboratory, 25000 Besancon, France. Electronic address:

Objectives: The aim of this study was to analyse influence of the fetal head position and the type of instrument used (forceps, vacuum, OdonAssist™) on perineal deformation, during simulated vaginal deliveries monitored by stereophotogrammetry.

Methods: An exploratory study was conducted using mannequins simulating vaginal births. Fifty simulated deliveries were performed with different fetal head positions and instruments: Pajot's forceps, Kiwi-vacuum, and OdonAssist™.

View Article and Find Full Text PDF

A 54-year-old male underwent a low anterior resection in 2015 for rectal adenocarcinoma. He presented to the emergency department with a two-week history of fever, perianal pain, an erythematous, warm, and actively draining mass. Physical examination revealed a perianal abscess in the left posterior gluteal region, with a palpable internal fistulous orifice 3 cm from the anal margin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!