Perineural hematoma may result in nerve inflammation and myelin damage.

Reg Anesth Pain Med

From the *Department of Anaesthesiology and Intensive Care Therapy and †Institute of Pathology, Philipps University Marburg, Marburg, Germany; ‡St Luke's and Roosevelt Hospital Center, University Hospital of Columbia University, College of Physicians and Surgeons, New York City, NY; and §Department of Anaesthesiology, University of Regensburg, Regensburg, Germany.

Published: May 2016

Background And Objectives: Perineural hematoma may occur during performance of peripheral nerve blocks. The aim of this study was to test the hypothesis that an iatrogenic hematoma in the immediate vicinity of a peripheral nerve may cause histologic evidence of nerve injury.

Methods: Fifty milliliters of autologous blood was injected adjacent to the right sciatic nerve in 20 anesthetized female pigs. In order to discern between blood-related volume and immune effects, 50 mL of albumin was injected at the same location in an additional 22 pigs. Either blood or albumin was injected in random order. The left sciatic nerve served as a negative control in all animals, that is, either no needle placement or needle placement without injection. After 48 hours, the nerves were resected. The grade of nerve injury was scored from 0 (no injury) to 3 (severe injury) by histologic analysis of myelin tissue and inflammatory cells.

Results: Eighty-two nerve specimens were examined. Injury scores were significantly (P < 0.01) higher in the blood injection (n = 20; median [interquartile range] 2 [2-2]) and albumin injection (n = 22, 1 [1-2]) conditions compared with the no needle placement (n = 22, 0 [0-1]) and "dry needle placement" (n = 20, 1 [0-1]) conditions. Widespread inflammatory changes were seen in the blood injection group, in which 15% of nerve specimens showed damage to myelin.

Conclusions: Our data suggest that hematoma adjacent to nerve tissue may result in structural nerve injury and inflammatory changes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/AAP.0000000000000170DOI Listing

Publication Analysis

Top Keywords

needle placement
12
nerve
11
perineural hematoma
8
peripheral nerve
8
sciatic nerve
8
albumin injected
8
nerve injury
8
nerve specimens
8
blood injection
8
inflammatory changes
8

Similar Publications

This study aimed to evaluate the impact of different manipulation methods and storage environments on the microstructural, chemical, and mechanical properties of calcium-enriched mixture (CEM) cement. Four sample groups were examined, including nondried (ND-I) and dried (D-I) groups placed directly in an incubator, dried samples stored in phosphate-buffered saline (PBS) (D-P), and dried samples stored in distilled water (D-W). Various analyses, including Vickers microhardness, compressive strength, Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) were conducted after incubating the samples for 7 days.

View Article and Find Full Text PDF

Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).

Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.

Methods: Multicenter, real-world, retrospective study.

View Article and Find Full Text PDF

Purpose: Spinal cord stimulation (SCS) is pivotal in treating chronic intractable pain. To elucidate the mechanism of action among conventional and current novel types of SCSs, a stable and reliable electrophysiology model in the consensus animals to mimic human SCS treatment is essential. We have recently developed a new in vivo implantable pulsed-ultrahigh-frequency (pUHF) SCS platform for conducting behavioral and electrophysiological studies in rats.

View Article and Find Full Text PDF

Background: The aim of this study was to compare microwave ablation (MWA) with and without prior placement of an intra-arterial catheter for the purpose of application of contrast medium (CM).

Methods: 148 patients (45 female, 65.1 ± 14.

View Article and Find Full Text PDF

Objective: To discuss the elbow skin fold extension line in Kirschner wire internal fixation of extended supracondylar humeral fractures in children.

Methods: The clinical data of 58 children with extended supracondylar fractures of the humerus who met the selection criteria between August 2021 and July 2024 were retrospectively analyzed. In 28 cases, needle placement of medial epicondyle of humerus was performed with the assistance of the elbow skin fold extension line (study group), and 30 cases were assisted by routine touch of the medial epicondyle of the humerus (control group).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!