Background: We are aware of no study that has compared press-fit condylar Sigma fixed-bearing and mobile-bearing total knee prostheses in the same patients after more than ten years of follow-up. The purpose of the current study was to compare these two implants with respect to the functional and radiographic results, prevalence of osteolysis, and overall revision rates at a mean of 12.1 years of follow-up.
Methods: The study consisted of a consecutive series of 444 patients (mean age [and standard deviation], 66.5 ± 7.4 years) who underwent simultaneous bilateral total knee arthroplasty, with one side treated immediately after the other. All of the patients received a press-fit condylar Sigma mobile-bearing prosthesis on one side and a press-fit condylar Sigma fixed-bearing prosthesis on the contralateral side. The minimum duration of follow-up was ten years (mean, 12.1 years; range, ten to thirteen years). At the time of each follow-up visit, the patients were assessed clinically and radiographically.
Results: Postoperative total knee scores (95 and 94 points), Western Ontario and McMaster Universities Osteoarthritis Index (19 and 18 points), University of California, Los Angeles activity score (both prostheses, 5 points), range of motion (129° ± 6.3° and 127° ± 6.8°), and radiographic findings did not differ significantly between the press-fit condylar Sigma mobile and fixed-bearing designs at the final follow-up. The prevalence of aseptic loosening (1.4% and 1.8%) did not differ significantly between the mobile and fixed-bearing implant designs. No knee in either group had osteolysis. The estimated survival rate with revision as the end point was 98.2% (95% confidence interval, 91% to 99%) and 97.5% (95% confidence interval, 91% to 99%) at 12.1 years for the mobile and fixed-bearing implant groups, respectively.
Conclusions: The results of the present long-term clinical study suggest that excellent clinical and radiographic results were achieved with both the press-fit condylar Sigma mobile and fixed-bearing cruciate-retaining total knee designs. We found no significant clinical advantage for a mobile-bearing over a fixed-bearing total knee prosthesis.
Level Of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2106/JBJS.M.01130 | DOI Listing |
J Long Term Eff Med Implants
November 2023
Holland Orthopaedic and Arthritic Centre, Sunnybrook Health Sciences, Toronto, Canada.
The aim of this study was to evaluate the outcomes of hybrid fixation technique in aseptic condylar revision total knee arthroplasty (rTKA). A retrospective consecutive study of patients with minimal metaphyseal bone loss who underwent aseptic rTKA with press-fit cementless femoral stems and short cemented tibial stems. Primary outcome measure was mechanical failure.
View Article and Find Full Text PDFActa Biomed
August 2023
Department of Orthopaedic and Traumatology, Orthopaedic and Trauma Center, University of Turin, via Zuretti 29, 10121, Turin.
Background And Aim: Revision total knee arthroplasty(rTKA) is a challenging and expensive treatment for orthopedic surgeons who have to deal with poor bone quality and bone loss. This study aims to retrospectively evaluate the clinical and radiological results of patients undergoing rTKA and porous metaphyseal sleeves in AORI type II and III bone defects.
Methods: We conducted a retrospective series of continuous patients treated for mechanical failure of TKA.
Int J Surg Case Rep
July 2023
Istanbul University, Istanbul Faculty of Medicine, Dept. of Orthopaedics and Traumatology (retired), Capa 34093 Fatih, Istanbul, Turkey.
Introduction And Importance: Total knee arthroplasty (TKA) in the neuropathic unstable knee (NUK) setting is classically a challenging orthopedic problem due to intraoperative technical difficulties and a higher frequency of periprosthetic complications. More recently, satisfactory results have been reported using improved constraints, stems and revision-type TKA components. The study aims to present long-term results of a small case series with NUK osteoarthritis reconstructed by a condylar, semi-constrained prosthesis with a polygonal, hydroxyapatite-coated (HA-coated) press-fit stem.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
September 2023
Service d'orthopédie-traumatologie, CHU de Rennes, Rennes, France.
Introduction: The optimal technique for component fixation in revision total knee arthroplasty (rTKA) remains controversial: full cementation (FC) versus hybrid fixation (HF), which involves press-fit stem with cement fixation in the metaphyseal and epiphyseal zones. Previous series have either demonstrated the superiority of one or the other of these techniques or their equivalence. However, few studies have compared these 2 methods for rTKA using the Legacy® Constrained Condylar Knee (LCCK) prosthesis (Zimmer, Warsaw, Indiana, USA).
View Article and Find Full Text PDFJ Orthop
August 2022
Department of Orthopaedics, Sunshine Hospitals, Paradise Circle, Secunderabad, Telangana, India.
Purpose: This study aimed to audit the effects of vitamin D3 on the early functional outcomes, the incidence of nosocomial COVID-19 infection and complications in patients undergoing elective Total Knee Arthroplasty (TKA).
Methods: This was a retrospective study involving patients undergoing primary unilateral TKA between January 2020 to May 2021 operated by a single surgeon using a single implant. Participants were divided into two cohorts, Deficient-vitamin D3 level <20 ng/ml and Sufficient-vitamin D3 level ≥20 ng/ml.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!