A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery. | LitMetric

Closed blood conservation device for reducing catheter-related infections in children after cardiac surgery.

Crit Care Nurse

Menglin Tang is a nurse in the pediatric intensive care unit at West China Hospital of Sichuan University, Chengdu, Sichuan, China.Mei Feng is a nurse in the pediatric intensive care unit at West China Hospital of Sichuan University.Lijun Chen is a nurse in the pediatric intensive care unit at West China Hospital of Sichuan University.Jinmei Zhang is a nurse in the pediatric intensive care unit at West China Hospital of Sichuan University.Peng Ji is a resident physician, Department of Anesthesiology, West China Hospital of Sichuan University.Shuhua Luo is an attending physician, Department of Cardiac Surgery, West China Hospital of Sichuan University.

Published: October 2014

Background: Arterial catheters are potential sources of nosocomial infection.

Objective: To investigate use of a closed blood conservation device in preventing catheter-related bloodstream infections in children after cardiac surgery.

Methods: Children with an indwelling arterial catheter after cardiac surgery were randomly assigned to 2 groups: a control group with a conventional 3-way stopcock in the catheter system and an interventional group with the conservation device in the catheter system. Catheter tips, catheter intraluminal fluid, and blood samples obtained from the catheter and peripherally were cultured for microbiological analysis. RESULTS Intraluminal fluid contamination was significantly lower (P = .03) in the interventional group (3 of 147 catheters) than in the control group (10 of 137 catheters). The 2 groups did not differ significantly in the rate of tip colonization (9 of 147 vs 12 of 137; P = .40) or in the number of catheter-related bloodstream infections (0 of 147 vs 2 of 137; P = .21).

Conclusion: Use of a closed blood conservation device could decrease the incidence of catheter-related contamination of intraluminal fluid.

Download full-text PDF

Source
http://dx.doi.org/10.4037/ccn2014416DOI Listing

Publication Analysis

Top Keywords

conservation device
16
closed blood
12
blood conservation
12
intraluminal fluid
12
infections children
8
children cardiac
8
cardiac surgery
8
catheter-related bloodstream
8
bloodstream infections
8
control group
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!