Flush-mounted probe diagnostics for argon glow discharge plasma.

Rev Sci Instrum

Science and Technology on Space Physics Laboratory, Beijing 100076, China.

Published: September 2014

A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%. Moreover, the space potential and effective electron temperature calculated from electron energy distribution function measured by the FP is consistent with that measured by the CP over the operated discharge current and pressure ranges. These results present the FP can be used as a reliable diagnostic tool in the stable laboratory plasma and also be anticipated to be applied in other complicated plasmas, such as tokamaks, the region of boundary-layer, and so on.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4895644DOI Listing

Publication Analysis

Top Keywords

flush-mounted probe
8
argon glow
8
glow discharge
8
discharge plasma
8
plasma parameters
8
space potential
8
effective electron
8
electron temperature
8
density determined
8
plasma
6

Similar Publications

Currently, flow regime identification for closed channels has mainly consisted of direct subjective methods. This presents a challenge when dealing with opaque test sections of the pipe or at gas-liquid flow rates where unclear regime transitions occur. In this paper, we develop a novel real-time objective flow regime identification tool using conductance data and kernel methods.

View Article and Find Full Text PDF

An array of flush-mounted and toroidally elongated Langmuir probes (henceforth called rail probes) have been specifically designed for the Alcator C-Mod's vertical target plate divertor and operated over multiple campaigns. The "flush" geometry enables the tungsten electrodes to survive high heat flux conditions in which traditional "proud" tungsten electrodes suffer damage from melting. The toroidally elongated rail-like geometry reduces the influence of sheath expansion, which is an important effect to consider in the design and interpretation of flush-mounted Langmuir probes.

View Article and Find Full Text PDF

In this work, a double flush-mounted probe for measuring plasma parameters was designed and fabricated. The method to determine the plasma density and electron temperature using a floating double flush-mounted probe was characterized. To validate this method, the measurement results in an argon glow discharge plasma, including the electron density and temperature measurements, were compared with those obtained using a single probe and a double probe.

View Article and Find Full Text PDF

Flush-mounted probe diagnostics for argon glow discharge plasma.

Rev Sci Instrum

September 2014

Science and Technology on Space Physics Laboratory, Beijing 100076, China.

A comparison is made between plasma parameters measured by a flush-mounted probe (FP) and a cylindrical probe (CP) in argon glow discharge plasma. Parameters compared include the space potential, the plasma density, and the effective electron temperature. It is found that the ion density determined by the FP agrees well with the electron density determined by the CP in the quasi-neutral plasma to better than 10%.

View Article and Find Full Text PDF

Biasing, acquisition, and interpretation of a dense Langmuir probe array in NSTX.

Rev Sci Instrum

October 2010

Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA.

A dense array of 99 Langmuir probes has been installed in the lower divertor region of the National Spherical Torus Experiment (NSTX). This array is instrumented with a system of electronics that allows flexibility in the choice of probes to bias as well as the type of measurement (including standard swept, single probe, triple probe, and operation as passive floating potential and scrape-off-layer SOL current monitors). The use of flush-mounted probes requires careful interpretation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!