Diaphyseal osteotomy after post-traumatic malalignment.

Curr Rev Musculoskelet Med

Orthopaedics and Trauma Department, 3rd Division, Città della Salute e della Scienza, via Zuretti 29, 10126, Torino, Italy,

Published: December 2014

AI Article Synopsis

Article Abstract

Tibia and femur shaft fractures can sometimes lead to post-traumatic deformities. Correction by means of circular external frames is a valuable option. The aim of this article is to give an overview of the problem and to focus on some important technical issues of the preoperative planning, the surgical procedures, and the postsurgical management of circular external fixators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4596217PMC
http://dx.doi.org/10.1007/s12178-014-9244-9DOI Listing

Publication Analysis

Top Keywords

circular external
8
diaphyseal osteotomy
4
osteotomy post-traumatic
4
post-traumatic malalignment
4
malalignment tibia
4
tibia femur
4
femur shaft
4
shaft fractures
4
fractures lead
4
lead post-traumatic
4

Similar Publications

Mass vaccination against peste des petits ruminants (PPR) in two southern states of India, namely Andhra Pradesh and Karnataka, has reduced disease outbreaks significantly. The sporadic outbreaks reported now can be attributed in part to the recurring movement of sheep and goats between these contiguous states. This study assessed the present level of economic burden and impact of vaccination on the local system (one state), considering the exposure from the external system (neighboring state) using a system dynamic (SD) model.

View Article and Find Full Text PDF

Limb lengthening and deformity correction techniques, particularly distraction osteogenesis, have significantly evolved in pediatric orthopedics. This study examines the temporal changes of key biochemical markers-vascular endothelial growth factor (VEGF), fibroblast growth factor 1 (FGF-1), and the propeptide of type I collagen (P1NP)-during the limb lengthening process. Twenty pediatric patients (aged 13-16) underwent distraction osteogenesis using the Circular Hexapod External Fixator.

View Article and Find Full Text PDF

Circular Economy Applied to Sludge Minimization: The STAR Project.

Membranes (Basel)

January 2025

Department of Civil, Environmental, Architectural Engineering and Mathematics, University of Brescia, Via Branze 43, 25123 Brescia, Italy.

The management of biological sludge from wastewater treatment plants (WWTPs) poses a significant environmental challenge due to increasing sludge production and the presence of emerging pollutants. This study investigates an innovative solution by integrating a thermophilic aerobic membrane reactor (TAMR) into the sludge treatment line of a medium-size WWTP, aiming to minimize biological sludge output while enhancing resource recovery. The study involved a six-month monitoring of an industrial-scale TAMR system, assessing the reduction in volatile solids (VSs) in thickened sludge and evaluating the compatibility of TAMR residues with conventional activated sludge (CAS) systems.

View Article and Find Full Text PDF

Although the accumulation of random genetic mutations has been traditionally viewed as the main cause of cancer progression, altered mechanobiological profiles of the cells and microenvironment also play a major role as a mutation-independent element. To probe the latter, we have previously reported a microfluidic cell-culture platform with an integrated flexible actuator and its application for sequential cyclic compression of cancer cells. The platform is composed of a control microchannel in a top layer for introducing external pressure, and a polydimethylsiloxane (PDMS) membrane from which a monolithically-integrated actuator protrudes downwards into a cell-culture microchannel.

View Article and Find Full Text PDF

Objective: To report clinical outcomes of skeletally immature dogs with antebrachial deformities secondary to premature closure of the distal radial physis (PCDRP) treated with angular corrections and distraction osteogenesis using circular external skeletal fixation (CESF).

Study Design: Retrospective multi-institutional case series.

Animals: A total of 12 client-owned dogs with premature distal radial physeal closure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!