The purpose of this research is to study the influence of double pulse laser induced breakdown spectroscopy (DP-LIBS) on the sensitivity of Cu in water. The water solution of Cu was tested by collinear DP-LIBS in this article. The results show that spectral intensity of Cu can be enhanced obviously by DP-LIBS, compared with single pulse laser induced breakdown spectroscopy (SP-LIBS). Besides, the experimental results were significantly impacted by delay time between laser pulse and spectrometer acquisition, delay time of double laser pulse and energy of laser pulse and so on. The paper determined the best conditions for DP-LIBS detecting Cu in water. The optimal acquisition delay time was 1 380 ns. The best laser pulse delay time was 25 ns. The most appropriate energy of double laser pulse was 100 mJ. Characteristic analysis of spectra of Cu at 324.7 and 327.4 nm was done for quantitative analysis. The detection limit was 3.5 microg x mL(-1) at 324.7 nm, and the detection limit was 4.84 microg x mL(-1) at 327.4 nm. The relative standard deviation of the two characteristic spectral lines was within 10%. The calibration curve of characteristic spectral line, established by 327.4 nm, was verified with 500 microg x mL(-1) sample. Concentration of the sample was 446 microg x mL(-1) calculated by the calibration curve. This research shows that the detection sensitivity of Cu in water can be improved by DP-LIBS. At the same time, it had high stability.
Download full-text PDF |
Source |
---|
J Cosmet Dermatol
January 2025
Hospital for Skin Diseases, Shandong First Medical University, Jinan, Shandong Province, China.
Ultramicroscopy
January 2025
Christian Doppler Laboratory for Sustainable Hard Coatings at the Department of Materials Science, Montanuniversität Leoben, Franz-Josef-Straße 18, 8700 Leoben, Austria.
The impact of the laser wavelength on accuracy in elemental composition analysis in atom probe tomography (APT) was investigated. Three different commercial atom probe systems - LEAP 3000X HR, LEAP 5000 XR, and LEAP 6000 XR - were systematically compared for a TiN model coating studying the effect of shorter laser wavelengths, especially in the deep ultraviolet (DUV) range, on the evaporation behavior. The findings demonstrate that the use of shorter wavelengths enhances the accuracy in elemental composition, while maintaining similar electric field strengths.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410072, China.
High power pulse generators are moving in the direction of compact, solid-state, and stable working in a relatively long time. In this paper, a compact pulse forming line-Marx type high power pulse generator, based on a ceramic pulse forming line and a spark gap switch with carbide modified graphite electrodes, is studied numerically and experimentally. Specifically, a ceramic based pulse forming line with high relative permittivity was used to achieve long pulse duration in a limited dimension.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, 69117 Heidelberg, Germany.
We describe a simple gas expansion ion source based on static discharge voltages and a commercially available pulsed valve. The discharge is initiated by the gas pulse itself between two high voltage electrodes, without the need for fast voltage switches or complex timing schemes. The ion source very reliably produces intense bursts of molecular ions (with currents exceeding 100 μA during the pulse-on phase) with only minor pulse-to-pulse variations in intensity and pulse shape.
View Article and Find Full Text PDFCureus
December 2024
Implantology and Periodontology, Almón Brito IPD (Implantology, Periodontology, Oral Diagnostic) Institute, Caracas, VEN.
Oral paresthesia occurs when one of the nerves in the region is injured, usually the inferior alveolar and/or lingual nerve, after dental procedures such as the extraction of lower third molars. The objective of this study was to describe the case of a patient who received photobiomodulation (PBM) therapy for paresthesia of the inferior alveolar nerve (IAN) caused by the extraction of mandibular third molars. The protocol used involved a super-pulsed diode laser with dual wavelengths of 810 nm and 980 nm, 1 W, 60 seconds, 12.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!