Pectus Excavatum is an anatomical deformation characterized by a depression of the anterior chest wall. Nuss technique (representing the current clinical golden standard) consists in the introduction of a corrective metal bar, in order to raise the sternum in its anatomic natural position. Nowadays, the bar plays purely a mechanical/corrective action and is kept implanted for about three years, supporting up to a maximum force of 250 N. Our study aims at optimizing the procedure of correction, in terms of monitoring the bar effect, minimizing the body response, and facilitating the bar removal. The sensorized Nuss bar prototype inserted in a platform for telemedicine described in this article is able to monitor in vitro pressure data variations, with more than 150 discrete measurements during the operating period. This behavior is promising for future clinical applications, in which the device could be exploited to monitor the forces at work, thus, providing a customized therapeutic protocol, which in turn may optimize the period of implant. The sensorized bar was also provided with a polymeric coating, able to influence human dermal fibroblast behavior in vitro. This highlights the possibility to minimize, in future in vivo applications, tissue fibrotic responses.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4239956PMC
http://dx.doi.org/10.3390/s141018096DOI Listing

Publication Analysis

Top Keywords

sensorized nuss
8
nuss bar
8
pectus excavatum
8
bar
7
bar patient-specific
4
patient-specific treatment
4
treatment pectus
4
excavatum pectus
4
excavatum anatomical
4
anatomical deformation
4

Similar Publications

Development of an implantable sensor system for strain, temperature, and pH monitoring: comparative evaluation of titanium and resorbable magnesium plates.

Bioact Mater

January 2025

Laboratory of Metal Physics and Technology, Department of Materials, ETH Zurich, 8093 Zurich, Switzerland.

Biodegradable magnesium is a highly desired material for fracture fixation implants because of its good mechanical properties and ability to completely dissolve in the body over time, eliminating the need for a secondary surgery to remove the implant. Despite extensive research on these materials, there remains a dearth of information regarding critical factors that affect implant performance in clinical applications, such as the pH and mechanical loading conditions. We developed a measurement system with implantable strain, temperature, pH and motion sensors to characterize magnesium and titanium plates, fixating bilateral zygomatic arch osteotomies in three Swiss alpine sheep for eight weeks.

View Article and Find Full Text PDF

Novel haptics technologies are urgently needed to bridge the gap between entirely physical world and fully digital environment to render a more realistic and immersive human-computer interaction. Current virtual reality (VR) haptic gloves either deliver limited haptic feedback or are bulky and heavy. The authors develop a haptic glove or HaptGlove, an untethered and lightweight pneumatic glove, that allows users to "physically" interact in a VR environment and enables both kinesthetic and cutaneous sensations naturally and realistically.

View Article and Find Full Text PDF

In the context of all-digital radar systems, phase-modulated continuous wave (PMCW) based on pseudorandom binary sequences (PRBSs) appears to be a prominent candidate modulation scheme for applications such as autonomous driving. Among the reasons for its candidacy are its simplified transmitter architecture and lower linearity requirements (e.g.

View Article and Find Full Text PDF

Eating and rumination variables were recorded using a pressure sensor integrated into the noseband of a halter in 60 cows with left displaced abomasum (LDA) before and after postoperative administration of flunixin meglumine (FM). Group 1 comprised 9 healthy control cows that were used to establish reference intervals. Group 2 included 60 cows with LDA that received one of the following three treatments: intravenous saline solution (2A, n=20), 1.

View Article and Find Full Text PDF

Purpose: For the evaluation of the chest wall deformity, we adopted a non-invasive 3D body scanning system. The objective of this study is to evaluate surgical effect on the whole thorax using 3D scanning technique before and after Nuss procedure.

Methods: We performed 3D body scanning using Structure Sensor (Occipital Inc, USA) in 11 symmetric patients (average age 13 ± 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!