Comparison of concentric and eccentric bench press repetitions to failure.

J Strength Cond Res

1Department of Kinesiology, Vanguard University, Costa Mesa, California; 2Center for Sport Performance, California State University, Fullerton, California; 3School of Nutrition and Health Promotion, Arizona State University, Phoenix, Arizona; 4Rocky Mountain University of Health Professions, Provo, Utah; and 5College of Allied Health, California Baptist University, Riverside, California.

Published: April 2015

AI Article Synopsis

  • Eccentric muscle actions (ECC) involve muscle lengthening while still forming connections between actin and myosin and can generate greater force than concentric actions (CON).
  • A study measured the one-rep max (1RM) strength of 30 healthy men in both ECC and CON bench press and assessed their performance at various percentages of 1RM.
  • Results indicated ECC produced a significantly higher 1RM (116 kg) than CON (94 kg) and allowed more repetitions at 90% 1RM (ECC: 7.67 vs. CON: 4.57), suggesting ECC may enhance strength and resistance to fatigue, highlighting the need for specialized training approaches.

Article Abstract

Eccentric muscle actions (ECC) are characterized by muscle lengthening, despite actin-myosin crossbridge formation. Muscles acting eccentrically are capable of producing higher levels of force compared with muscles acting concentrically. The purpose of this study was to determine whether ECC bench press yields greater strength than concentric (CON) as determined by 1 repetition maximum (1RM). Additionally, a comparison was made examining differences in the number of repetitions to failure at different relative intensities of 1RM. Thirty healthy men (age = 24.63 ± 5.6 years) were tested for 1RM in CON and ECC bench press and the number of repetitions completed at 60, 70, 80, and 90% 1RM. For CON repetitions, the weight was mechanically lowered to the chest, and the participant pressed it up until the elbows were fully extended. The ECC bench press consisted of lowering a barbell from a fully extended elbow position to the chest in a continuous controlled manner for 3 seconds as determined by electronic metronome. Paired t-tests showed that ECC 1RM (115.99 ± 31.08 kg) was significantly (p ≤ 0.05) greater than CON 1RM (93.56 ± 26.56 kg), and the number of repetitions completed at 90% 1RM was significantly (p ≤ 0.05) greater in ECC (7.67 ± 3.24) as compared with CON (4.57 ± 2.21). There were no significant differences in number of completed repetitions during CON and ECC bench press at 60, 70, and 80% 1RM. These data indicate that ECC actions yield increased force capabilities (∼120%) as compared with CON in the bench press and may be less prone to fatigue, especially at higher intensities. These differences suggest a need to develop unique strategies for training eccentrically.

Download full-text PDF

Source
http://dx.doi.org/10.1519/JSC.0000000000000713DOI Listing

Publication Analysis

Top Keywords

bench press
24
ecc bench
16
number repetitions
12
repetitions failure
8
ecc
8
muscles acting
8
1rm
8
differences number
8
1rm con
8
con ecc
8

Similar Publications

: The purpose of this study was to compare the effects of resistance training on stable versus unstable surfaces on strength performance in young judokas. : The study included 18 young judokas (age: 13.2 ± 1.

View Article and Find Full Text PDF

Background: One repetition maximum (1RM) is a vital metric for exercise professionals, but various testing protocols exist, and their impacts on the resulting 1RM, barbell kinetics, and subsequent muscular performance testing are not well understood. This study aimed to compare two previously established protocols and a novel self-led method for determining bench press 1RM, 1RM barbell kinetics, and subsequent muscular performance measures.

Methods: Twenty-four resistance-trained males (n = 12, 24 ± 6.

View Article and Find Full Text PDF

This study first investigated how the probability of winning collision events is affected by technical characteristics among world-class, international female rugby union players, and second, whether enhanced performance of these technical characteristics was related to physical attributes. Carry and tackle events from 16 international matches played by a top-two world ranking team were coded according to technical characteristics and performance outcomes. Binary classification tree models revealed that carry performance was successfully predicted ( < 0.

View Article and Find Full Text PDF

Maternal and fetal responses to acute high-intensity resistance exercise during pregnancy.

Br J Sports Med

December 2024

Program for Pregnancy and Postpartum Health, Physical Activity and Diabetes Laboratory, Faculty of Kinesiology, Sport, and Recreation, Women and Children's Health Research Institute, Alberta Diabetes Institute, University of Alberta, Edmonton, Alberta, Canada

Objective: To examine maternal and fetal cardiovascular responses to high-intensity resistance exercise in pregnancy.

Methods: 10 healthy pregnant (26.4±3.

View Article and Find Full Text PDF

The aim of this study was to compare barbell velocities at different intensities and estimated 1-RM with actual 1-RM measured with different measuring tools in bench presses and squats. Fourteen resistance-trained athletes (eight men, six women, age 28.1 ± 7.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!