Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Context: Prostate-specific antigen (PSA) is a 34-kDa glycoprotein with chymotrypsin-like enzyme activity that circulates both in free forms and complexed to various enzyme inhibitors including antichymotrypsin and α2-macroglobulin. Prostate-specific antigen bound to α2-macroglobulin is not detected by commercial PSA immunoassays.
Objective: To develop a mass spectrometry assay that detects the same forms of PSA as the immunoassays, which could serve as a reference for harmonizing PSA immunoassays.
Design: Prostate-specific antigen was immune extracted from serum, trypsin was digested, and the LSEPAELTDAVK peptide was quantitated on an API 5000 spectrometer. Calibrators were made by adding 10% free and 90% antichymotrypsin-bound PSA to female sera. The assay was standardized to the World Health Organization 96/670 reference standard. Validation of clinical utility and comparisons with 2 immunoassays (Roche cobas and Beckman Access) were performed using frozen sera aliquots from 100 men undergoing prostate biopsy (50 negative, 50 with cancer) and 5 serial samples collected over time from 5 men with advanced prostate cancer.
Results: The antibody extraction efficiency was greater than 99%. The assay has an analytic range from 1.2 to 76 ng/mL, with precision ranging from 8.6% at 1.5 ng/mL to 5.4% at 27 ng/mL. The mass spectrometry assay correlated well with 2 immunoassays. All 3 assays showed statistically equivalent separation of prostate cancer from benign disease using receiver operating characteristic curve analysis.
Conclusions: This mass spectrometry assay can reliably measure PSA concentrations in human serum and could serve as a reference standard for harmonizing PSA immunoassays.